14. Pb (lead-acid) programs
This program is designed for charging and discharging lead / sulphuric acid and lead / gel
batteries with nominal voltages of exactly 2, 4, 6, 12 and 24 V (1, 2, 3, 6 and 12 cells).
Caution: the charger will not recognize lead-acid batteries with other nominal voltages, and
such batteries must not be connected to it.
Lead-acid batteries behave entirely differently to Ni-Cd and Ni-MH batteries. Lead-acid batteries
can only deliver relatively low currents relative to their capacity, and similar restrictions very
definitely apply to charging. Manufacturers usually state 14 to 16 hours for achieving nominal
capacity when recharging at the normal charge current. The „normal“ charge current is defined
as one tenth of the battery’s nominal capacity. Example: battery capacity = 12 Ah —> normal
charge current = 1.2 A. In contrast to Ni-Cd and Ni-MH batteries, lead-acid chargers generally
monitor the battery’s voltage in order to determine when it is fully charged.
Lithium type select program
This is actually the most important set-up program for
Lithium batteries. In the Select program you enter the
battery type and battery capacity. It is vital to enter this
information with the greatest care. Check it very thoroughly,
as the charger derives all the other charge parameters from
the settings you enter here.The battery type you select
(LiPo, LiIo or LiFe) affects the charge termination voltage. If you find that a Lithium battery has
unexpectedly been charged only to the 2/3 full mark, you have probably set the incorrect battery
type at this point.Caution: if you set an incorrect value at this point, the battery may be damaged
irreparably, and could even explode!
The final charge voltage can be adjusted in 0.01V steps.
The max. charge voltage for LiPo is 4.2V, for LiIo 4.1V, for LiFe 3.6V. To store the batteries, adjust
the charge voltage about 0.4V lower as the maximum charge voltage.
At charging/discharging the battery types will be displayed as followed:
LiPo (LiMn) = LP
LiIo = LI
LiFe = LF
Pb
MANUAL-
program
Pb
discharge
program
MODE MODE
________________
________________
Lithium type
LiPo 4.20V/C
INC
+
-
DEC
Lithium cell count
________________
________________
***LiPo cells***
2 cells ( 7.73V)
INC
+
-
DEC
When you have connected the battery to the charger, hold
the START button pressed in for about two seconds and
the screen will display the cell count of the Lithium pack. If
the pack contains 1 or 2 cells, the charger detects and
sets the number of cells fully automatically. If the pack
contains more than two cells, you may have to adjust the
cell count manually using the INC / DEC buttons, as the
automatic circuit is unable to detect more than three cells
reliably. On the right-hand side you will see the voltage of
the pack connected to the charger. Pressing the START
button again initiates the charge process. Only cell
number should flash. If cell number and battery voltage
are correct, press the Enter button to start.
! Caution ! Please take great
care to set the correct cell
count and battery type. If you
make a mistake, the battery
could explode and burst into
flames !
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Graupner Ultramat 18 - 6470 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Graupner Ultramat 18 - 6470 in the language / languages: English, German, French as an attachment in your email.

The manual is 0,68 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info