637232
42
Zoom out
Zoom in
Previous page
1/107
Next page
42
Lithium manual program
The charger automatically sets the charge current of 1C based on this information.
When you connect the pack to the charger and start the charge process, the charge current starts at
0.00 A and slowly rises to the set limit.However, please do not be surprised if the charger does not
reach the current you have set, because the charge program constantly monitors the battery voltage
in order to prevent the pack infl ating, provided that the voltage of the individual cells in the pack is the
same.When the charger automatically reduces the charge current, the screen displays the message
END, alternating with the reduced charge current.
This program charges the battery using the capacity (charge
current) which you set.
Before you initiate the actual program you must set the charging
current (range 0.1A...10.0 A, left of the screen) and the capacity
of the pack (range 50...20.000 mAh, right on the screen) using
the INC / DEC buttons. Switch between the charge current and
the capacity parameters by using the ENTER button.
If the charged capacity reaches 110% of the adjusted capacity,
the charging process is stopped for safety reasons.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
L P -
C 4 . 0 A 4 0 0 0 m A h
Lithium discharge program
The purpose of this program is to determine the residual capa-
city of a Lithium pack which has not been fully discharged.
The program discharges the pack using the set discharge cur-
rent (0.1 ... 5.0 A, left of screen) down to the set fi nal discharge
voltage (2.5 ... 3.7 V per cell, right of screen). It is not possible
to set a fi nal discharge voltage below 2.5 V per cell, otherwise
the battery will suffer permanent damage.
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
L P - D :
1 . 0 A 2 . 5 V / C
DEC
INC
+
-
DECINC
+
-
ENTER
DEC
INC
+
-
DECINC
+
-
ENTER
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
L i P o m a n u a l
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
L i P o d i s c h a r g e
Lithium storage program
This program does charge or discharge the battery to the best
storage voltage.
The program does charge or discharge the battery to the
adjusted storage voltage, which is best for longer storage of
a Li-battery.
Best store voltage:
LiPo: 3,8...3,9V/cell
LiIo: 3,7...3,8V/cell
LiFe: 3,3...3,4V/cell
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
< 2 . 0 A
3 . 8 0 V / C
DEC
INC
+
-
DECINC
+
-
ENTER
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
L i P o s t o r e
2 sec.
2 sec.
2 sec.
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Graupner ULTRA TRIO PLUS 16 - 6469 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Graupner ULTRA TRIO PLUS 16 - 6469 in the language / languages: English, German, French, Italian as an attachment in your email.

The manual is 2,54 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info