467107
195
Zoom out
Zoom in
Previous page
1/200
Next page
195
Appendix
Graupner|SJ HoTT General Engine Module
Order No. 33610
General sensor for Graupner|SJ HoTT receivers and models with
internal-combustion or electric power system:
2 x temperature and voltage measurements with warning thresholds •
for min. and max. voltage and min. and max. temperature
Individual cell measurement with min. voltage warning thresholds•
Voltage, current and capacity measurement with warning thresholds •
for min. and max. voltage, max. capacity and max. current
Programmable current limiting•
Current measurement with 2 x 1 mOhm shunt resistors in parallel = •
0.5 mOhm
Rev-count measurement and warning thresholds for min. and max. •
rotational speed
Fuel measurement with warning thresholds in 25% increments (re-•
quires software update)
User-variable warning time: OFF, 5, 10, 15, 20, 25, 30 seconds, con-•
stant
User-variable warning repeat time: constant, 1, 2, 3, 4, 5 min, once•
2 x temperature measurement, optionally 0 to 120°C or 200°C, also •
voltage measurement up to 80 V DC
1 x rev-count measurement up to 100,000 rpm with two-blade pro-•
peller
1 x speed controller / servo input, 1 x speed governor input, 1 x •
speed controller / servo output for rotational speed governor
etc. see product at www.graupner.de•
Graupner|SJ HoTT General Air Module
Order No. 33611
General sensor for Graupner|SJ HoTT receivers and models with
internal-combustion or electric power system:
Vario with altitude signals, climb and descent signals, and addition-•
al warning thresholds for min. altitude, max. altitude, climb and two-
stage descent rate
Altitude indicator (-500 … +3000 m), storage of min. and max. alti-•
tude
2 x temperature and voltage measurements with warning thresholds •
for min. and max. voltage and min. and max. temperature
Individual cell measurement with min. voltage warning thresholds•
Voltage, current and capacity measurement with warning thresholds •
for min. and max. voltage, max. capacity and max. current
Rev-count measurement and programmable speed governor, also •
warning thresholds for min. and max. rotational speed
Fuel measurement with warning thresholds in 25% increments (re-•
quires software update)
User-variable warning time: OFF, 5, 10, 15, 20, 25, 30 seconds, con-•
stant
User-variable warning repeat time: constant, 1, 2, 3, 4, 5 min, once•
2 x temperature measurement, optionally 0 to 120°C or 200°C, also •
voltage measurement up to 80 V DC
1 x rev-count measurement up to 100,000 rpm with two-blade pro-•
peller
etc. see product at www.graupner.de•
Graupner|SJ HoTT Electric Air-Module
Order No. 33620
General sensor for Graupner|SJ HoTT receivers and electric-powered
models:
Vario with altitude signals, climb and descent signals, and addition-•
al warning thresholds for min. altitude, max. altitude, two-stage climb
and descent rate
Altitude indicator (-500 … +3000 m), storage of min. and max. alti-•
tude.
2 x temperature and voltage measurements with warning thresholds •
for min. and max. voltage and min. and max. temperature
Individual cell measurement 2 ... 14S with min. voltage warning •
thresholds
Voltage, current and capacity measurement with warning thresholds •
for min. and max. voltage, max. capacity and max. current
User-variable warning time: OFF, 5, 10, 15, 20, 25, 30 seconds, con-•
stant
User-variable warning repeat time: constant, 1, 2, 3, 4, 5 min, once•
2 x temperature measurement, optionally 0 to 120°C or 200°C, also •
voltage measurement up to 80 V DC
1 x speed controller input, 1 x speed controller output for power re-•
duction due to low voltage of individual cells
1 x current, voltage and capacity measurement, up to 150 A (peak 1 •
sec. 320 A) and up to 60 V
1 x individual cell monitoring for 2 - 14S Lithium batteries (LiPo, LiIo, •
LiFe)
etc. see product at www.graupner.de•
195


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Graupner MX-16 HoTT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Graupner MX-16 HoTT in the language / languages: English as an attachment in your email.

The manual is 4,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Graupner MX-16 HoTT

Graupner MX-16 HoTT User Manual - Dutch - 188 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info