467107
146
Zoom out
Zoom in
Previous page
1/200
Next page
146
Program description: Telemetry menu
ALL MAX (Servo travel on the “+” side)
In this line you can set the maximum servo travel for the
servo test on the plus side of control travel.
2000 μs corresponds to full travel, 1500 μs corresponds
to the neutral position.
Ensure that the servos do not strike their mechanical
end-stops during the test routine.
ALL MIN (Servo travel on the “-” side)
In this line you can set the maximum servo travel for the
servo test on the minus side of control travel.
1000 μs corresponds to full travel, 1500 μs corresponds
to the neutral position.
Note:
Ensure that the servos do not strike their mechanical
end-stops during the test routine.
TEST
In this line you can start and stop the receiver’s integral
servo test.
Touch the central SET button of the right-hand touch-key
to activate the input field:
RX SERVO TEST
ALL–MIN : 1000µsec
ALL–MAX : 2000µsec
ALARM VOLT : 3.8V
ALARM TEMP–:–10°C
ALARM TEMP+: 55°C
CH OUTPUT TYPE:ONCE
TEST : STOP
Now select START with one of the arrow buttons of the
right-hand touch-key:
RX SERVO TEST
ALL–MIN : 1000µsec
ALL–MAX : 2000µsec
ALARM VOLT : 3.8V
ALARM TEMP–:–10°C
ALARM TEMP+: 55°C
CH OUTPUT TYPE:ONCE
TEST : START
Touch the central SET button of the right-hand touch-
key to start the test-run. The input field now reverts from
highlighted to “normal”:
RX SERVO TEST
ALL–MIN : 1000µsec
ALL–MAX : 2000µsec
ALARM VOLT : 3.8V
ALARM TEMP–:–10°C
ALARM TEMP+: 55°C
CH OUTPUT TYPE:ONCE
TEST : START
To stop the servo test, re-activate the input field as de-
scribed previously, then select STOP and confirm your
choice with the SET button of the right-hand touch-key.
ALARM VOLT (low receiver voltage warning)
ALARM VOLT monitors the receiver voltage. The thresh-
old can be set to any value within the range 3.0 to 6.0
Volt. If the voltage falls below the set alarm limit, an
audible signal (interval beeping, long / short) is trig-
gered, and VOLT.E” flashes at top right in all “RX …
screen displays:
RX SERVO
REVERSE : OFF
CENTER : 1500µsec
TRIM : –000µsec
TRAVEL– : 150%
OUTPUT CH: 01
TRAVEL+ : 150%
PERIOD : 20msec
VOLT.E
The parameter R-VOLT“ is also highlighted in the “RX
DATAVIEW” display:
S–STR100% R–TEM.+28°C
L PACK TIME 00010msec
L.R-VOLT:03.5V
S–QUA100%S–dBM–030dBM
SENSOR1 :00.0V 00°C
SENSOR2 :00.0V 00°C
R-VOLT :03.7V
RX DATAVIEW VOLT.E
ALARM TEMP +/- (receiver temperature monitor)
These two options monitor the temperature of the
receiver: a lower limit value “ALARM TEMP-” (-20 ...
+10°C) and an upper limit value “ALARM TEMP+” (50 ...
80°C) can be programmed. If the temperature exceeds
the upper limit or falls below the lower one, an audible
signal (continuous beeping) is triggered, and “TEMP.E
appears at top right in all receiver displays. The param-
eter “R-TEM“ is also highlighted in the RX DATAVIEW
display.
Ensure that the receiver remains within the permitted
temperature range under all flight conditions (ideally
between -10 and +50°C).
CH OUTPUT TYPE
At this point you can select how the receiver outputs are
to be addressed.
ONCE•
RX SERVO TEST
ALL–MIN : 1000µsec
ALL–MAX : 2000µsec
ALARM VOLT : 3.8V
ALARM TEMP–:–10°C
ALARM TEMP+: 55°C
TEST : START
CH OUT TYPE:ONCE
146


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Graupner MX-16 HoTT at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Graupner MX-16 HoTT in the language / languages: English as an attachment in your email.

The manual is 4,49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Graupner MX-16 HoTT

Graupner MX-16 HoTT User Manual - Dutch - 188 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info