33028_mc_28_Teil2_jh
Time1
The times are only measured if the switch or control switch, assigned
in the line "Lap time/Time tab." of the "Phase timer" menu, is
"closed”. The frequency of the switch actuation is displayed in the
basic display. This counter will be highlighted as soon as the switch
for the "Time1" timer is "open", the timer is hold (stopped).
In the stopped state, the recorded switching times can be succes-
sively read out with the selection keys.
Time2
"Time2" stores both the "Off" and "On" times of the associated
switch. Each time the switch is operated, the time count starts again
and the counter is incremented by "1". The timer can be stopped at
any time via the central ESC key on the left touch panel without actu-
ating the switch. Running the switch while the stopped timer is
stopped increases the counter by 1 and restarts the "Time2" timer.
In the stopped state, the recorded data of the "Time2" timer can be
successively read out with the selection keys.
Motor
This column is only available if “forward” or “backward” is set in the
line "Motor to CH1" of the "Model type" menu.
If you select "yes", the channel 1 on the receiver is controlled by the
CH1 control stick. The brake system in the "Wing mixer" menu is
switched off.
If you select "no", the channel 1 on the receiver is not controlled by
the CH1 control stick. The setting of the throttle position "Off" in
"Throttle min front/rear" is held. The brake system in the "Wing
mixer" menu is active and is actuated by the CH1 control stick.
Sw.time
Move the marking frame with the selection buttons over the "Ph.
timer" column to the right side. to reach this column
Set the switchover time to the respective phase. All functions in the
phase are activated within the selected time.
Note
If individual servos are switched without delay, the channels in the
"Delayed channels" menu are set accordingly.
Brake settings
normal
Normal
Off
Pha1
Pha2
Pha3
Name Motor
Pha4
Pha5
+
+
Normal
Start
Tr a ck
yes
yes
yes
yes
yes
Pha1
Pha2
Pha3
Name Sw.time
Pha4
Pha5
+
+
Normal
Start
Tr a c k
0.1s
0.1s
0.1s
0.1s
0.1s
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Graupner MC-28 4D at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Graupner MC-28 4D in the language / languages: English as an attachment in your email.

The manual is 17,31 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info