505353
44
Zoom out
Zoom in
Previous page
1/54
Next page
FIRMWARE 1.0.0.49 GXW42XX USER MANUAL PAGE 44 OF 54
g. < =1> - add a leading 1 to all numbers dialed, vice versa will remove a 1
from the number dialed
h. | - or
Example 1: {[369]11 | 1617xxxxxxx} –
Allow 311, 611, 911, and any 10 digit numbers of leading digits 1617
Example 2: {^1900x+ | <=1617>xxxxxxx}
Block any number of leading digits 1900 and add prefix 1617 for any dialed 7 digit
numbers
Example 3: {1xxx[2-9]xxxxxx | <2=011>x+}
Allow any length of number with leading digit 2 and 10 digit-
numbers of leading digit
1 and leading exchange numbe
r between 2 and 9; If leading digit is 2, replace
leading digit 2 with 011 before dialing.
3. Default: Outgoing - {x+}
Example of a simple dial plan used in a Home/Office in the US:
{ ^1900x. | <=1617>[2-9]xxxxxx | 1[2-9]xx[2-9]xxxxxx | 011[2-9]x. | [3469]11 }
Explanation of example rule (reading from left to right):
^1900x. - prevents dialing any number started with 1900
<=1617>[2-9]xxxxxx -
allows dialing to local area code (617) numbers by dialing 7
numbers and 1617 area code will be added automatically
1[2-9]xx[2-9]xxxxxx |- allows dialing to any US/Canada Number with 11 digits length
011[2-9]x. - allows international calls starting with 011
[3469]11 - allow dialing special and emergency numbers 311, 411, 611 and 911
Note: In some cases user wishes to
dial strings such as *123 to activate voice mail or other
application provided by service provider. In this case * should be predefined inside dial plan
feature and the Dial Plan will be: { [x*]+ }.
Subscribe for
MWI
Default is No. When set to “Yes” a SUBSCRIBE for Message Waiting Indication will be sent
periodically.
Send Anonymous
If this parameter is set to “Yes”, the “From” header along with Privacy and
P_
Asserted_Identity headers in outgoing INVITE message will be set to anonymous, blocking
Caller ID.
Anonymous Call
Rejection
Default is No. If set to Yes, incoming calls with anonymous Caller ID will be rejected with 486
Busy message.
Special Feature
Default is Standard. Choose the selection to meet some special requirements from
Softswitch vendors. Example of vendors - CBCOM, RNK.
44


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Grandstream GXW4248 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Grandstream GXW4248 in the language / languages: English as an attachment in your email.

The manual is 0,78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info