590771
101
Zoom out
Zoom in
Previous page
1/160
Next page
GMC-I Messtechnik GmbH 101
Automatic Test – Administration
Test Step Specification – External Measurement
Measurement results from an external test instrument can be en-
tered for this test step. Whether or not the DUT has passed the
test or not is determined with additional entries for Min-Max limit
values and setpoint.
External measurements and visual inspections can be configured
such that voltage to the test socket is switched on during execu-
tion.
Short-form Operating Instructions
Setting Up an External Measurement
Ð Enter a new test step:
Ð Select external measurement
General Index Card
Ð Designation: Enter for purpose of identification/archiving
appears as a a headline in other windows for
improved clarity and cross-reference.
Ð Class: External measurement
Ð Description: Enter comment if required
Evaluation Index Card
The limit values must be entered here which result in failure of the
test in the event that they are exceeded (MaxLimitValue) or fallen
short of (MinLimitValue). A setpoint can be entered here as well.
See also section 6.3.6, “Evaluation of Measured Values for Indi-
vidual Test Steps”.
Ð Unit: Enter unit of measure
Unit Unit of measure for limit value setpoint or tol.
Ð Test condition: In progress
Ð Min Limit Value See entry examples in table on page 98
Ð Max Limit Value See entry examples in table on page 98
Ð Setpoint: Target value
Ð Tolerance: In progress
Note
Select a limit value which either complies with or is stricter
than the legally binding regulations.
101


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt SECUSTAR FM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt SECUSTAR FM in the language / languages: English as an attachment in your email.

The manual is 1,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info