590771
14
Zoom out
Zoom in
Previous page
1/160
Next page
14 GMC-I Messtechnik GmbH
Operating Overview – Connections
Connections
Reset key In the event that the system no longer reacts, briefly
press the recessed button with the stylus (at the back
of the Prüfsystem to the left of the Ethernet port).
Ethernet 10
RS 232 (internal)
USB-Sl
USB2
Compact flash II
USB1
USB3 USB4
Connection for mains operation
Connections for probes
Standard socket (test
socket) for connecting the DUT
S1 S2
-------USB-Master-------
for printer or sensor
USB slave, to PC (option)
Slot for memory
card
Wand holder
Reset key
for rebooting the test system
Fuse
Connection for probe
PSG10 (Z745Y)
Connection Application
Top connections
Standard socket Test socket with safety class detection
Ethernet 10 Network connection, 10 MBit
CF slot For inserting compact flash II memory cards
USB1 USB master, e.g. for keyboard, printer, barcode scanner or
500 mA sensor
USB2 USB3 USB4 USB master, e.g. for keyboard, printer, or sensor, 100 mA
USB-SI USB slave, to PC (in preparation)
RS232 Interface, for service only
Bottom connections
Sockets 1 and 2 Test probe connection (max. 300 V CAT II)
Sockets 3 and 4 Current sensor connection, 1 mV/mA (max. 300 V CAT II)
Inlet socket Supply power connection (90 to 240 V, 50 to 400 Hz)
Connection Application
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt SECUSTAR FM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt SECUSTAR FM in the language / languages: English as an attachment in your email.

The manual is 1,75 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info