21.5 List of Abbreviations and their Meanings
RCCBs (residual current devices / RCDs)
I
Tripping current
I
N
Nominal residual current
I
F
Rising test current (residual current)
PRCD Portable residual current device
PRCD-S:
with protective conductor detection and monitoring
PRCD-K:
with undervoltage trigger and protective conductor monitoring
RCD- Selective RCCB
R
E
Calculated earthing or earth electrode loop resistance
SRCD Socket residual current device (permanently installed)
t
a
Time to trip / breaking time
U
I
Contact voltage at moment of tripping
U
IN
Contact voltage
relative to nominal residual current I
N
U
L
Contact voltage limit value
Overcurrent Protective Devices
I
K
Calculated short-circuit current (at nominal voltage)
Z
L-N
Line impedance
Z
L-PE
Loop impedance
Earthing
R
B
Operational earth resistance
R
E
Measured earthing resistance
R
ELoop
Earth electrode loop resistance
Low-Value Resistance at
Protective, Earthing and Bonding Conductors
R
LO+
Bonding conductor resistance (+ pole to PE)
R
LO
Bonding conductor resistance (– pole to PE)
Insulation
R
E(ISO)
Earth leakage resistance (DIN 51953)
R
ISO
Insulation resistance
R
ST
Standing surface insulation resistance
Z
ST
Standing surface insulation impedance
Current
I
A
Breaking current
I
L
Leakage current (measured with current clamp trans-
former)
I
M
Measuring current
I
N
Nominal current
I
P
Test current
Voltage
f Line voltage frequency
f
N
Nominal voltage rated frequency
U Voltage drop as %
U Voltage measured at the test probes during and after
insulation measurement R
ISO
U
Batt
Battery voltage
U
E
Earth electrode voltage
U
ISO
For measurement of R
ISO
: test voltage, for ramp function:
triggering or breakdown voltage
U
L-L
Voltage between two phase conductors
U
L-N
Voltage between L and N
U
L-PE
Voltage between L and PE
U
N
Nominal line voltage
U
3~
Highest measured voltage during determination of
phase sequence
U
S-PE
Voltage between probe and PE
U
Y
Conductor voltage to earth
S
93


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt PROFITEST MTECH plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt PROFITEST MTECH plus in the language / languages: English as an attachment in your email.

The manual is 2,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info