GMC-I Messtechnik GmbH 5
16.2 Transferring Distributor Structures ........................................... 66
16.3 Creating a Distributor Structure in the Test Instrument ........... 66
16.3.1 Creating Structures (example for electrical circuit) ......................... 67
16.3.2 Searching for Structural Elements ................................................ 68
16.4 Saving Data and Generating Reports ........................................ 69
16.4.1 Use of Barcode Scanners and RFID Readers ................................. 70
17 Operating and Display Elements ....................................71
18 LED Indications, Mains Connections and Potential Differences 73
19 Characteristic Values ......................................................82
20 Maintenance ...................................................................87
20.1 Firmware Revision and Calibration Information ....................... 87
20.2 Rechargeable Battery Operation, and Charging ....................... 87
20.2.1 Charging Procedure with Charger for Z502R ................................. 87
20.3 Fuses ........................................................................................ 87
20.4 Housing ..................................................................................... 87
21 Appendix .........................................................................88
21.1
Tables for the determination of maximum or minimum display values
under consideration of maximum measuring uncertainty: ...................88
21.2 At which values should/must an RCD actually be tripped?
Requirements for Residual Current Devices (RCDs) ................. 90
21.3 Testing Electrical Machines per DIN EN 60204 –
Applications, Limit Values ......................................................... 91
21.4 Periodic Testing per DGUV provision 3 (previously BGV A3) – Limit
Values for Electrical Systems and Operating Equipment .......... 92
21.5 List of Abbreviations and their Meanings ................................. 93
21.6 Keyword Index .......................................................................... 94
21.7 Bibliography .............................................................................. 95
21.7.1 Internet Addresses for Additional Information ............................... 95
22 Repair and Replacement Parts Service
Calibration Center and Rental Instrument Service .........96
23 Recalibration ..................................................................96
24 Product Support .............................................................96
1 Scope of delivery
1Test instrument
1 Earthing contact plug insert (country-specific)
1 2-pole measuring adapter and 1 cable for expansion into a
3-pole adapter (PRO-A3-II)
2 Alligator clips
1 Shoulder strap
1 Compact Master Battery Pack (Z502H)
1 Charger Z502R
1 DAkkS calibration certificate
1USB cable
1 Condensed operating instructions
1 Supplement Safety Information
Detailed operating instructions for download from our website
at www.gossenmetrawatt.com
2 Applications
The PROFITEST MASTER and SECULIFE IP measuring and test instru-
ments allow for quick and efficient testing of protective measures
in accordance with DIN VDE 0100, part 600:2008
(Erection of low-
voltage installations; tests – initial tests), as well as
ÖVE-EN 1 (Aus-
tria), NIV/NIN SEV 1000 (Switzerland) and other country-specific
regulations.
The test instrument is equipped with a microprocessor and com-
plies with IEC 61557/EN 61557/VDE 0413 regulations:
Part 1: General requirements
Part 2: Insulation resistance
Part 3: Loop resistance
Part 4:
Resistance of earth connection and equipotential bonding
Part 5: Earth resistance
Part 6: Effectiveness of residual current devices (RCD) in TT, TN
and IT systems
Part 7: Phase sequence
Part 10:Electrical safety in low-voltage systems up to 1000 V AC
and 1500 V DC – Equipment for testing, measuring or
monitoring of protective measures
Part 11:Effectiveness of type A and type B residual current moni-
tors (RCMs) in TT, TN and IT systems
The test instrument is especially well suited for:
•System setup
Initial start-up
Periodic testing
Troubleshooting in electrical systems
All of the values required for approval reports (e.g. for ZVEH) can
be measured with this instrument.
All acquired data can be archived, in addition to the measurement
and test reports which can be printed out at a PC. This is of spe-
cial significance where product liability is concerned.
The applications range of the test instruments covers all alternat-
ing and three-phase current systems with nominal voltages of
230 V / 400 V (300 V / 500 V) and nominal frequencies of 16
2
/
3
/
50 / 60 / 200 / 400 Hz.
The following can be measured and tested with the instruments:
Voltage / frequency / phase sequence
Loop impedance / line impedance
Residual current devices (RCDs)
Insulation monitoring devices (IMDs) (only
MXTRA
&
SECULIFE IP
)
Residual current monitoring devices (RCMs) (only MXTRA)
Earthing resistance / earth electrode potential
Standing surface insulation resistance / insulation resistance
Earth leakage resistance
Low-value resistance (potential equalization)
Leakage currents with current transformer clamp
Residual voltage (only MXTRA)
Voltage drop
Leakage current with leakage current adapter
Meter start-up (not
SECULIFE IP
)
Cable length
Refer to section 21.3 regarding testing of electrical machines in
accordance with DIN EN 60204.
Refer to section 21.4 regarding periodic testing in accordance
with DGUV provision 3 (previously BGV A3).
2.1 Using Cable Sets and Test Probes
2 or 3-pole measuring adapter included
2-pole measuring adapter with 10 m cable as optional acces-
sory: PRO-RLO II (Z501P)
KS24 cable set as optional accessory (GTZ3201000R0001)
Measurements per DIN EN 61010-031 may only be performed in
environments in accordance with measuring categories III and IV
with the safety cap attached to the test probe at the end of the
measurement cable.
In order to establish contact inside 4 mm jacks, the safety caps
have to be removed by prying open the snap fastener with a
pointed object (e.g. the other test probe).
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt PROFITEST MTECH plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt PROFITEST MTECH plus in the language / languages: English as an attachment in your email.

The manual is 2,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info