590777
85
Zoom out
Zoom in
Previous page
1/96
Next page
GMC-I Messtechnik GmbH 85
1)
U > 230 V with 2 or 3-pole adapter only
2
1
·
/ 2
·
IN > 300 mA and 5
·
IN > 500 mA and If > 300 mA only up to U
N
230 V !
3
The transformation ratio selected at the clamp (1 ... 1000 mV/A) must be set in the “Type” menu with the rotary switch in the “SENSOR” position.
4
Where R
Eselective
/R
Etotal
< 100
Special Function MPRO, MXTRA
5
Signal frequency without interference signal
6
PRO-RE (Z501S) adapter cable for test plug, for connecting earth probes (E-Set 3/4)
7
PRO-RE/2 (Z502T) adapter cable for test plug, for connecting the generator clamp
(E-CLIP2)
8
Generator clamp: E-CLIP2 (Z591B)
9
Clamp meter: Z3512A (Z225A)
10
Where RE.sel/RE < 10 or clamp current > 500 µA
11
Where RE.H/RE 100 and RE.E/RE 100
12
Where d = 20 m
13
Where d = 2 m
14
Where Z
L-PE
< 0.5 , I
k
> U
N
/0.5 is indicated
15
)Only where RANGE = 20 k
16
Only where RANGE = 50 k or AUTO
Key: D = digits, rdg. = measured value (reading)
R
ISO
R
ISO
, R
E ISO
1 ... 999 k
1.00 ... 9.99 M
10.0 ... 49.9 M
1 k
10 k
100 k
I
K
= 1.5 mA 50 k... 500 M
U
N
= 50 V
I
N
= 1 mA
k range
±(5% v.M.+10D)
Mrange
(5% rdg. + 1 d)
k
range
(3% rdg.+10d)
M
range
(3% rdg. + 1 d)
●●
1 ... 999 k
1.00 ... 9.99 M
10.0 ... 99.9 M
1 k
10 k
100 k
U
N
= 100 V
I
N
= 1 mA
1 ... 999 k
1.00 ... 9.99 M
10.0 ... 99.9 M
100 ... 200 M
1 k
10 k
100 k
1 M
U
N
= 250 V
I
N
= 1 mA
1 ... 999 k
1.00 ... 9.99 M
10.0 ... 99.9 M
100 ... 500 M
1 k
10 k
100 k
1 M
U
N
= 500 V
U
N
= 1000 V
I
N
= 1 mA
U
10 ... 999 V–
1.00 ... 1.19 kV
1 V
10 V
10 ... 1.19 kV (3% rdg. + 1 d)
(1.5% rdg. + 1 d)
R
LO
R
LO
0.01 ... 9.99
10.0 ... 199.9
10 m
100 m
I
m
200 mA
I
m
< 200 mA
0.1 ... 5.99
6.0 ... 100
U
0
= 4.5 V (4% rdg. + 2 d) (2% rdg. + 2 d)
SEN-
SOR
I
L/Amp
0 ... 99.9 mA 0.1 mA
5 ... 1000 mA
3
(10% rdg.+8d) (4% rdg.+7d)
100 ... 999 mA 1 mA (10% rdg.+3d) (4% rdg. + 2 d)
0 ... 99.9 A 0.1 A
5 ... 150 A
3
(8% rdg. + 2 d) (3% rdg. + 2 d)
100 ... 150 A 1 A (8% rdg. + 1 d) (3% rdg. + 1 d)
0 ... 99.9 mA 0.1 mA
5 ... 1000 mA
3
0.05 ... 10 A
3
0.5 ... 100 A
3
5 ... 1000 A
3
(7% rdg.+8d) (4% rdg.+7d)
100 ... 999 mA 1 mA (5% rdg.+3d) (2% rdg. + 2 d)
1.0 ... 9.99 A 0.01 A (4% rdg. + 2 d) (2% rdg. + 2 d)
10.0 ... 99.9 A 0.1 A (4% rdg. + 2 d) (2% rdg. + 2 d)
100 ... 999 A 1 A (4% rdg. + 1 d) (2% rdg. + 1 d)
1.00 ... 1.02 kA 0.01 kA (4% rdg. + 1 d) (2% rdg. + 1 d)
0 ... 99.9 mA 0.1 mA
1 V/A 30 ... 1000 mA
3
U
N
= 120/230/
400 V
f
N
= 50/60 Hz
(7% rdg.+100d)
(4% rdg.+100d)
100 ... 999 mA 1 mA (6% rdg.+12d) (3% rdg.+12d)
1.0 ... 9.99 A 0.01 A 100 mV/A 0.3 ... 10 A
3
(6% rdg.+12d) (3% rdg.+12d)
10.0 ... 99.9 A 0.1 A 10 mV/A 3 ... 100 A
3
(5% rdg.+11d) (2% rdg.+11d)
Uez
0.0 ... 99.0 mV 0.1 mV
400 k 1000 mV
(3% rdg. + 2 d) (2% rdg. + 2 d)
100 ... 999 mV 1 mV (3% rdg. + 1 d) (2% rdg. + 1 d)
Func-
tion
Measured
Quantity
Display Range
Reso-
lution
Input
Impedance /
Test Cu rrent
Measuring
Range
Nominal
Values
Measuring
Uncertainty
Intrinsic
Uncertainty
Connections
Plug
Insert
1
2-Pole
Adapter
3-Pole
Adapter
Probe
Clamp
WZ12C Z3512A
MFLEX
P300
Func-
tion
Measured
Quantity
Display Range
Reso-
lution
Test Current/
Signal
Frequen
cy
5
Measuring Range
Measuring
Uncertainty
Intrinsic
Uncertainty
Connections
Adapter for Test Plug
Current Clamps
PRO-RE PRO-RE/2 Z3512A Z591B
RE
BAT
RE, 3-pole
0.00 ... 9.99
10.0 ... 99.9
100 ... 999
1.00 ... 9.99 k
10.0 ... 50.0 k
0.01
0.1
1
0.01 k
0.1 k
16 mA/128 Hz
1.6 mA/128 Hz
0.16 mA/128 Hz
0.16 mA/128 Hz
0.16 mA/128 Hz
1.00 ... 19.9
5.0 ... 199
50 ... 1.99 k
0.50k ... 19.9k
0.50k ... 49.9k
(10% v.M.+10D)
+ 1
(3% v.M.+5D)
+ 0,5
6
RE, 4-pole (10% rdg.+10d) (3% rdg.+5d)
RE, 4-pole
Selective
With clamp meter
0.00 ... 9.99
10.0 ... 99.9
100 ... 999
1.00 ... 9.99 k
10.0 ... 19.9 k
15
10.0 ... 49.9 k
16
0.01
0.1
1
0.01 k
0.1 k
0.1 k
16 mA/128 Hz
16 mA/128 Hz
1.6 mA/128 Hz
0.16 mA/128 Hz
0.16 mA/128 Hz
0.16mA/128 Hz
1.00 ... 9.99
10.0 ... 200
(15% rdg.+10d)
(20% rdg.+10d)
10
(10% rdg.+10d)
(15% rdg.+10d)
69
Soil resistivity
(p)
0.0 ... 9.9 m
100 ... 999 m
1.00 ... 9.99 km
0.1 m
1 m
0.01 k
m
16 mA/128 Hz
1.6 mA/128 Hz
0.16 mA/128 Hz
0.16 mA/128 Hz
0.16mA/128 Hz
100 m ... 9.99 km
12
500 m ... 9.99 km
12
5.00 km ... 9.99 km
13
5.00 km ... 9.99 km
13
5.00 km ... 9.99 km
13
(20% rdg.+10d)
11
(12% rdg.+10d)
11
6
Probe distance
d (p)
0.1 ... 999 m
RE, 2 clamps
0.00 ... 9.99
10.0 ... 99.9
100 ... 999
1.00 ... 1.99 k
0.01
0.1
1
0.01 k
30 V / 128 Hz
0.10 ... 9.99
10.0 ... 99.9
(10% rdg.+5d)
(20% rdg.+5d)
(5% rdg.+5d)
(12% rdg.+5d)
798
85


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt PROFITEST MXTRA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt PROFITEST MXTRA in the language / languages: English as an attachment in your email.

The manual is 2,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt PROFITEST MXTRA

Gossen Metrawatt PROFITEST MXTRA User Manual - Dutch - 92 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info