590777
34
Zoom out
Zoom in
Previous page
1/96
Next page
34 GMC-I Messtechnik GmbH
10.5 Earthing Resistance Measurement, Mains Powered – Measurement of Earth Electrode Voltage (U
E
function)
This measurement is only possible with a probe (see section
10.4). Earth electrode potential U
E
is the voltage which occurs at
the earth electrode between the earth electrode terminal and ref-
erence earth if a short-circuit occurs between the phase conduc-
tor and the earth electrode. Measurement of earth electrode
potential is required by Swiss standard NIV/NIN SEV 1000.
Measuring Method
In order to determine earth electrode potential, the instrument first
measures earth electrode loop resistance R
ELoop
, and immedi-
ately thereafter earthing resistance R
E
. The instrument stores both
values and then calculates earth electrode potential with the fol-
lowing equation:
The calculated value is displayed at the display panel.
Select Measuring Function
Select Operating Mode Select measuring range
Connection
2-pole adapter and probe are connected.
Set Parameters
q Measuring range: 10 / U
E
q Connection type: 2-pole adapter + probe
q Contact voltage: UL < 25 V, < 50 V, < 65 V, see section 5.7 re-
garding freely selectable voltage.
q Test current waveshape: sinusoidal only in this case (full-wave)!
q System type: TN/TT, IT
q Transformer ratio: irrelevant in this case
Start Measurement
Note
The following diagram appears if the
2-pole adapter is connected incor-
rectly.
P
R
O
F
I
T
E
S
T
Ri
W
a
t
e
r
P
i
p
e
SE
2
E
1
B
U
E
U
N
R
E
R
E
Loop
-------------------=
R
E
Limit value:
R
E
> Limit Value
U
L
R
L
34


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt PROFITEST MXTRA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt PROFITEST MXTRA in the language / languages: English as an attachment in your email.

The manual is 2,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt PROFITEST MXTRA

Gossen Metrawatt PROFITEST MXTRA User Manual - Dutch - 92 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info