Table for the determination of maximum display values for low resistances by
making allowances for the instrument’s measuring error.
12 List of Abbreviations and their Meanings
Voltage
U Test voltage or nominal voltage
U
ISO
Rising test voltage for insulation testing
U~ Measured voltage (sinusoidal alternating voltage)
Temperature / Atmospheric Humidity
T / Temperature
F
REL
Relative atmospheric humidity
Resistance, Contact Current
LIMIT Limit value for insulation resistance, low-value resistance or
contact current
Offset Correction value of resistance for measurement cables
R
INS
Insulation resistance
R
LO
Low-value resistance (cable resistance)
13 Maintenance
13.1 Self-Test
Ð The self-test is started from the main menu with the Tes t key. The test
has a duration of several seconds.
The following information is displayed in the two headers:
Type/Cal: Device type / date of last calibration
Version: Software version and issue date
Self-tests for the items Chksum through LED are performed automatically,
one after the other, and are checked off or marked with a horizontal dash
if they are not passed.
Chksum1/2: Status display for internal testing (Each test must be
completed with a check mark. If not, the measuring and
test instrument may no longer be used. Please contact our
service center in this case.)
Relays: Each relay is switched twice.
LED: The U, LIMIT and NETZ/MAINS lamps each blink twice in red.
The PE lamp cannot be tested automatically!
As soon as the tests in the left-hand column have been completed, the
following tests must be started manually:
Limit Value
Maximum
Display Value
Limit Value
Maximum
Display Value
0.15 0.11
0.20 0.16 5.00 4.72
0.50 0.44 10.0 9.47
1.00 0.92 20.0 17.7
2.00 1.87 50.0 44.7
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRISO C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRISO C in the language / languages: English as an attachment in your email.

The manual is 0,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt METRISO C

Gossen Metrawatt METRISO C User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info