590650
24
Zoom out
Zoom in
Previous page
1/28
Next page
24 GMC-I Messtechnik GmbH
Overload Capacity
R
LO
Electronic protection disables start-up if
interference voltage is present.
U~ 500 V~ continuous
Electrical Safety
Standard IEC 61010-1:2010, EN 61010-1:2010
VDE Requirement VDE 0411 Part 1, 2011
Safety Class II
Polution degree 2
Measuring Category Insulation measurement – 1000 V DC –
no overvoltage
Voltage measurement – 500 V – CAT II
Fuses FF0.315-1000G
Electromagnetic Compatibility EMC
Interference Emission EN 61326-1:2006 Class B
Interference Immunity
EN 61326-1:
2006
Ambient Conditions
Nominal Temperature 0 ... +40 C
Operating Temperature 10 ... +50 C
Storage Temperature 20 ... +60 C (without batteries)
Relative Humidity to 75% (max. 85% for storage and transport),
no condensation allowed
Elevation max. 2000 m
Deployment indoors; outdoors only under the specified
ambient conditions
Mechanical Design
Display multiple dot matrix display
128 x 64 pixels (65 mm x 38 mm), illuminated
Dimensions 275 mm x 140 mm x 65 mm
Weight approx. 1.2 kg with batteries
Protection
Housing IP 52 per DIN VDE 0470 Part 1/EN 60529
with pressure compensating diaphragm made of
microporous ePTFE, non-aging, diam. 8 mm in
battery compartment cover
Extract from table on the meaning of IP codes
Data Interface
Type infrared interface (SIR/IrDa)
bidirectional, half-duplex
Format 9600 baud, 1 start bit, 1 stop bit, 8 data bits,
no parity, no handshake
Range max. 10 cm, recommended: < 4 cm
Display Values including Allowances for Measuring Error
Table for the determination of minimum display values for insulation resistance
by making allowances for the instrument’s measuring error.
IP XY
(1
st
digit X)
Protection against
foreign object entry
IP XY
(2
nd
digit Y)
Protection against
entry of water
2 12.5 mm
2 drops (with enclosure tilted 15)
3 2.5 mm
3 spraying water
4 1.0 mm
4 splashing water
5 dust protected 5 water jets
6 dust-tight 6 powerful water jets
Limit Value
Minimum
Display Value
Limit Value
Minimum
Display Value
020 k 025 k
100 k 111 k 100 M 111 M
200 k 219 k 200 M 219 M
500 k 541 k 500 M 541 M
0.20 M 0.25 M
0.50 M 0.57 M
1.00 M 1.11 M 1.00 G 1.11 G
2.00 M 2.19 M 2.00 G 2.19 G
5.00 M 5.41 M 5.00 G 5.41 G
10.0 M 11.1 M 10.0 G 11.1G
20.0 M 21.9 M 20.0 G 22.6 G
50.0 M 54.1 M 50.0 G 55.9 G
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRISO C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRISO C in the language / languages: English as an attachment in your email.

The manual is 0,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt METRISO C

Gossen Metrawatt METRISO C User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info