590624
51
Zoom out
Zoom in
Previous page
1/74
Next page
GMC-I Messtechnik GmbH 51
Device and Measuring Parameters
6.4 Entering Parameters – SETUP Menu
tiME Set Time
Entering the correct time makes it possible to acquire measured
values in real-time.
1nFo ... SET t iME
t iME SET: 10:24:18 (hh:mm:ss) 
Date and time must be reentered after replacing the batteries.
dAtE – Enter Date
Entering the current date makes it possible to acquire measured
values in real-time.
1nFo
... SET t iME ... dAtE
datE SET: 20.06 (DD: day . MM: month)

year SET: 2012 (YYYY: year)

Date and time must be reentered after replacing the batteries.
Addr – Set Device Address
See section 7.2 on page 57.
irStb – Status of the Infrared Receiver in the Stand-By Mode
See section 7.2 on page 57 regarding settings.
CoM ir / CoM bt – Interface Operating System Infrared / Bluetooth
Refer to section 7.2 on page 57 for instructions on switching bet-
ween the two systems.
bt pin – Pin for Bluetooth Interface
Refer to section 7.2 on page 57 on setting instructions.
APoFF – Specified Time for Automatic Shutdown and Continuous ON
The instrument is switched off automatically if the measured value
remains unchanged for a long period of time and if none of the
keys or the rotary switch have been activated before the specified
time “APoFF” (entered in minutes) has elapsed.
If the on setting is selected, the multimeter is set to continuous op-
eration and
ON appears in the display to the right of the battery
symbol. In this case, the multimeter can only be switched off
manually. The “on” setting can only be canceled by changing the
respective parameter, or by switching the instrument off manually.
In this case, the parameter is reset to 10 minutes.
1nFo
... SET t iME ... APoFF
APoFF SET: 10 ... 59 min on

(10 minutes = default setting)
Note
The auto power off function (APoFF parameter) is deactivated
when dangerous touch voltage is applied.
MEASURE
SETUP
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
MEASURE
SETUP
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
MEASURE
SETUP
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
51


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAHIT ULTRA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAHIT ULTRA in the language / languages: English as an attachment in your email.

The manual is 0,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info