590607
49
Zoom out
Zoom in
Previous page
1/72
Next page
GMC-I Messtechnik GmbH 49
Device and Measuring Parameters
6.1 Paths to the Various Parameters 6.2 List of All Parameters
bAtt
:
uers
ion
:
dAtE
:
t iME
:
0CCvP
:
1nFo
tEMPSEnd SET StorE
StArt
StoP
000.0
CLEAr
StArt
StoP
Sub-Menus / Parameters
rAtE
0..d iSP
A.d iSP
CL iP
APoFF
v_1so
Cap
r _sl
bEEP
irStb
Addr
dAtE
t iME
°C
°F
Main Menus
Query Set Set Set Set
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
01nfo
MEASURE
SETUP
020
.
00
V
DC
AC
TRMS
Selection
FUNC
ENTER
Selection
FUNC
ENTER
Selection
FUNC
ENTER
Selection
FUNC
ENTER
Parameter
Page: Header
0.d iSP 51: 0.diSP – show/hide leading zeros
Addr
55: Configuring Interface Parameters
A.d iSP 51: A.diSP – analog display: select display mode
APoFF
51: APoFF – specified time for automatic shutdown and continuous ON
bAtt
50: bAtt – query battery voltage
bEEP
52: bEEP – set limit value for continuity testing
Cap
53: CAP –
scaling factor for cable length measurement (capacitive linear electric
constant)
CLEAr
23: Measurement Data Recording
CL IP
46: Direct and Pulsating Current Measurement with Clip-On Current Sensor,
A DC and A (DC+AC)
47: Alternating Current Measurement with Clip-On Current Sensor, A AC and Hz
dAtE
50: dAtE – query date, 52: dAtE – enter date
EMpty
23: Measurement Data Recording
1nfo
50: Querying Parameters – InFo Menu (as moving letters)
irStb
55: Configuring Interface Parameters
0CCvP
23: Measurement Data Recording
rAtE
51: rAtE – set the sampling rate
r_sL
53: r _SL – set limit value for protective conductor resistance
SEnd
54: Activating the Interface
SET
51: Entering Parameters – SETUP Menu
StArt
23: Measurement Data Recording
StoP
store
tEMP
32: Temperature Measurement – Temp RTD
t iME
50: tiME – query time, 52: tiME – set time
49


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAHIT T-COM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAHIT T-COM in the language / languages: English as an attachment in your email.

The manual is 0,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt METRAHIT T-COM

Gossen Metrawatt METRAHIT T-COM Quick start guide - English, German - 2 pages

Gossen Metrawatt METRAHIT T-COM Quick start guide - Dutch - 3 pages

Gossen Metrawatt METRAHIT T-COM User Manual - Dutch - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info