5.9.4 Alternating Current Measurement with Clip-On Current Sensor,
A AC and Hz
Transformer Output, Voltage/Current
When a clip-on current sensor is connected to the multimeter
(V input), all current displays appear with the correct value in
accordance with the selected transformation ratio. The only
prerequisite is that the current sensor is equipped with at least
one of the below listed transformation ratios, and that the ratio
has been previously selected in the following menu (Cl ip 0FF)
(see also chapter 6.4).
Current Clip Setup Menu
1nFo
... SET rAtE ... CL IP
0ff/1 / 10/100/1000

Maximum allowable operating voltage is equal to the current
transformers nominal voltage.
When reading the measured value,
additional error resulting from the clip-on current sensor must also be
taken into consideration
(default value: Cl ip = 0ff = voltage dis-
play).
Trans. Ratio
CL IP
Measuring Ranges Clip Type
300 mV 3 V 30 V
1:1
1 mV / 1 mA
300.0 mA 3.000 A 30.00 A WZ12C
1:10
1m V / 10 mA
3.000 A 30.00 A 300.0 A
WZ12B, Z201A/B,
METRAFLEX
1:100
1m V / 100 mA
30.00 A 300.0 A 3,000 kA
Z202A/B,
METRAFLEX
1:1000
1 mV/1 A
300.0 A 3,000 kA 30.00 kA
Z202A/B, Z203A/B,
WZ12C, METRAFLEX
MEASURE
SETUP
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
0035.0
A
AC
TRMS
A~
Hz
1:1000
0050.1
Hz
AC
1:1000
FUNC
ENTER
V~
Hz
COM mA A
V
Tem p
Ω
aEb
~
R
x
Current
R
i
~ 9 MΩ
R
i
Measuring Ranges:
Hz: 1 Hz . . . 31 kHz
MEASURE
SETUP
... SET ... CL IP
FUNC
ENTER
FUNC
ENTER
 0ff
mA / A: see table
3 ranges: 300 Hz, 3 kHz and 30 kHz
47


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAHIT T-COM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAHIT T-COM in the language / languages: English as an attachment in your email.

The manual is 0,84 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt METRAHIT T-COM

Gossen Metrawatt METRAHIT T-COM Quick start guide - English, German - 2 pages

Gossen Metrawatt METRAHIT T-COM Quick start guide - Dutch - 3 pages

Gossen Metrawatt METRAHIT T-COM User Manual - Dutch - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info