22 GMC-I Messtechnik GmbH
Power Supply
Batteries
2 AA size batteries
alkaline manganese cells per
IEC LR6
Service Life
Battery Test
Automatic display of “
when battery voltage
falls to below approx. 2.3 V.
Battery Saver Circuit
The instrument switches itself off automatically if the measure-
ment value remains unchanged for about 10 minutes, and if
none of the operating elements are activated during this time.
This function is disabled in the transmission and menu modes,
or if “continuous on” has been activated.
Fuses
The current measuring ranges are protected by an internal
250 mA fusible link. A defective fuse can only be replaced by
GMC-I Service GmbH service personnel.
The voltage of the measuring current circuit may not exceed
600 V
eff
.
Electrical Safety
Protection Class
II per IEC/EN 61010-1:2010
/VDE 0411-1:2011
Measuring Category
II
Operating Voltage
600 V
Pollution degree
2
Test Voltage
3.7 kV~ per IEC/EN 61010-1:2010
/VDE 0411-1:2011
Electromagnetic Compatibility (EMC)
Interference Emission
EN 61326-1:2006 class B
Interference Immunity
EN 61326-1:2006
EN 61326-2-1:2006
Measuring Function
(with 2.5 Ah alkaline manganese cells)
Power
Consumption in mA
Service Life in
Hours
V DC, mA DC, °C/°F 100 16
V (AC + DC), mA (AC + DC) 105 15
Transmission mode, sampling rate: 100 ms
9600 baud 114
19200 baud 108
Transmission mode, sampling rate: 10 ms
9600 baud 156
19200 baud 146
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAHIT 30M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAHIT 30M in the language / languages: English as an attachment in your email.

The manual is 0,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info