590626
9
Zoom out
Zoom in
Previous page
1/28
Next page
GMC-I Messtechnik GmbH 9
GB
6.1 Zero Balancing (for V , mA , Ω and °C)
Ð Select the desired measuring range with the MAN|AUTO key.
Ð 2-Wire Resistance Measurement, Current Measurement
or Temperature Measurement with Pt100 or Pt1000:
short-circuit the positive and negative poles of sockets
„mAΩ
2
“ or „°C
2
, respectively.
Voltage Measurement, Temperature Measurement with
Thermocouple or 4-Wire Resistance Measurement:
short-circuit the positive and negative poles of sockets
„V/°C
TC
“ or „ΩSense“, respectively.
Ð Briefly press the MAN|AUTO and AVE/MIN|MAX keys
simultaneously.
The instrument acknowledges zero balancing with an
acoustic signal and
000.0000” (±1 digit, decimal place
depends upon measuring range) and the “ZERO” symbol
appear at the LCD
. The previously displayed measurement
value serves as a reference value (max. ±30000 digits).
Ð Zero balancing can be deleted:
– by pressing the MAN|AUTO key
after which deletion is acknowledged with an acoustic
signal,
– by selecting a different measuring function
– or by switching the instrument off.
Note
The zero balancing values (offset) for temperature measure-
ment are stored to memory in the resistance and/or voltage
measurement ranges and serve as reference values.
6.2 Voltage Measurements for Greater than 600 V
Voltages of greater then 600 V can be measured with a high-
voltage probe, for example the HV3 or the HV30. The earthing
terminal must be connected to ground for measurements of
this type. Observe all required safety precautions!
Function Measuring Range / Function
°
C
2
Pt100: 1 kΩΩ
2
Pt1000: 10 kΩΩ
2
°
C
4
Pt100: 1 k ΩΩ
4
Pt1000: 10 kΩΩ
4
°
C
TC
100 mV V
–V
Voltage Measurements for
Greater than 600 V
with the HV3 High-Voltage
Probe
black
black
red
x1000
x100
max. 3000 V
+
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAHIT 30M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAHIT 30M in the language / languages: English as an attachment in your email.

The manual is 0,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info