5 Minimum and Maximum Value Storage
“MIN/MAX” with Time Stamp
Minimum and maximum measurement values can be stored to
memory with the MIN/MAX function. The most important appli-
cation for this function is the determination of minimum and
maximum values during long-term observation of measure-
ment values. It can be activated for all measuring functions.
Ð Apply the measured quantity to the instrument.
Ð Select the measuring range with MAN|AUTO.
Ð Activate the MIN/MAX function.
Ð Repeated activation of the AVE/MIN| MAX key causes switching
amongst:
MAX > t > MIN > t > MAX ...
The measuring ranges can only be selected manually when the
“MIN/MAX” function is active.
The “MIN/MAX” function is deactivated, and stored MIN and
MAX values are deleted by pressing and holding the MIN/MAX
key (approx.. 1 s), by activating the rotary switch or by switch-
ing the instrument off and back on again.
6 Voltage Measurement
Ð Depending upon the voltage to be measured, set the
rotary switch to
V or V .
Ð Connect the measurement cables as shown. The “V” jack
should be grounded.
Note!
In the 600 V range, an intermittent acoustic signal
sounds alarm if the display value exceeds 600 V.
Attention!
!
Make absolutely certain that none of the current
ranges are active when the multimeter is connected
for voltage measurements! If the breaking limit val-
ues for the electronic fuse are exceeded due to
operator error, both the operator and the instrument
are in danger! Simultaneous connection to both cur-
rent and voltage measuring circuits is prohibited!
–V +
– /
+ ~
/
V
DC
V
AC
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAHIT 30M at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAHIT 30M in the language / languages: English as an attachment in your email.

The manual is 0,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info