GOSSEN-METRAWATT 3
Specifications METRA
Hit
18S
dB ranges
Measuring
function
Measuring range
METRA
Hit
18S
Resolution
Input impedance
Inherent deviation of the digital display
±(...% of meas. val. +... digits) for ref. conditions
Overload capacity
2)
Measuring
function
1) 1) 1) 1)
Overload
value
Overload
duration
V
300.00 mV 10 µV >10 G 5M//<40pF 0.05 + 3; 0.05 + 20
3)
0.5 + 30 (> 500 D)
1200 V
DC
AC
RMS
sinusoidal
cont.
V
3.0000 V 100 µV 11 M 1M//<40pF 0.05 + 3 0.3 + 30 (> 300 D)
30.000 V 1 mV 10 M 1M//<40pF 0.05 + 3 0.3 + 30 (> 300 D)
300.00 V 10 mV 10 M 1M//<40pF 0.05 + 3 0.3 + 30 (> 300 D)
1000.0 V 100 mV 10 M 1M//<40pF 0.05 + 3 0.3 + 30 (> 300 D)
dB
See table below Same as with V ± 0,5 dB
4)
dB
Voltage drop, approx.
1) 1)
mA
300.00 µA 10 nA 15 mV 15 mV 0.2 + 20 0.5 + 30 (> 300 D)
0.36 A cont.
mA
3.0000 mA 100 nA 150 mV 150 mV 0.2 + 10 0.5+ 30 (> 300 D)
30.000 mA 1 µA 30 mV 30 mV 0.05 + 10 0.5+ 30 (> 300 D)
300.00 mA 10 µA 300 mV 300 mV 0.2 + 10 0.5 + 30 (> 300 D)
A
3.0000 A 100 µA 150 mV 150 mV 0.5 + 10 0.75 + 30 (> 300 D)
12 A
5)
5 min
A
10.000 A 1 mA 400 mV 400 mV 0.5 + 10 0.75 + 30 (> 300 D)
No-load voltage Short circuit current
300.00 10m max. 4.00 V max. 1 mA 0.1 + 6; 0.1 + 30
3)
500 V
DC
AC
RMS
sinusoidal
10 min
3.0000 k 100 m max. 1.25 V max. 100 µA 0.1+6
30.000 k 1 max. 1.25 V max. 10 µA 0.1+6
300.00 k 10 max. 1.25 V max. 1 µA 0.1+6
3.0000 M 100 max. 1.25 V max. 0,1 µA 0.1+6
30.000 M 1k max. 1.25 V max. 0,1 µA 1.0+6
3.0000 V– 1mV max. 4.00 V 0.2+6
Discharge resist. U
0 max
F
3.000 nF 1 pF 1.5 M 4V 1.0 + 8; 1.0 + 60
3)
500 V
DC
AC
RMS
sinusoidal
10 min
F
30.00 nF 10 pF 1.5 M 4V 1.0 + 8; 1.0 + 30
3)
300.0 nF 100 pF 150 k 4V 1.0 + 3
3.000 µF1nF 150 k 4V 1.0 + 3
30.00 µF10nF 15 k 2V 1.0 + 3
300.0 µF 100 nF 1.5 k 2V 5.0 + 6
3000 µF1µF 1.5 k 2V 5.0 + 6
10000 µF10µF 1.5 k 2V 5.0 + 6
f
min
6)
Hz
300.00 Hz 0.01 Hz 10 Hz
0.1 + 3
7)
3kHz:
1200 V
cont.
Hz
3.0000 kHz 0.1 Hz 10 Hz
30 kHz:
30.000 kHz 1 Hz 10 Hz
300 V
100.00 kHz 10 Hz 100 Hz
100 kHz:
30 V
°C
Pt
100
– 200.0 ...
+ 100.0 °C
0.1 °C 0.5 Kelvin + 3
8)
500 V
DC
AC
eff
sinus
10 min
°C
+ 100.0 ...
+ 850.0 °C
0.1 °C 0,5+3
8)
Pt
1000
– 100.0 ...
+ 100.0 °C
0.1 °C 0.5 Kelvin + 3
8)
+ 100.0 ...
+ 850.0 °C
0.1 °C 0.5+3
8)
Measuring ranges
Display span at reference voltage
U = 0.775 V
Display span at reference voltage
U
ref
(V)
300 mV
3V
30 V
300 V
1000 V
– 48 dB ... – 8 dB
– 38 dB ... + 12dB
– 18 dB ... + 32 dB
+ 2 dB ... + 52 dB
+ 22 dB ... + 63 dB
– 40 dB ...+ 110 dB
– 60 dB ...+ 100 dB
– 80 dB ... + 80 dB
– 100 dB ... + 60 dB
– 110 dB ... + 40 dB
Display (dB) =
20 lg U
x
(V) / 0.775 V
Display (dB) =
20 lg U
x
(V) / U
ref
(V)
1) TRMS measurement
2) At –10 °C...+40°C
3) With zero setting; w/o zero setting
4) At a resolution of 0.01 dB
5) 16 A for 30 s
6) Lowest measurable frequency with sinusoidal measuring signal symmetrical to zero
7) Range 3 V : U
E
=1V
rms
. . . 10 V
rms
30 V : U
E
=10V
rms
. . . 100 V
rms
300 V :U
E
= 100 V
rms
. . . 1000 V
rms
8) Without sensor
Analog-digital multimeters
METRA 18S
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAHIT 12S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAHIT 12S in the language / languages: English as an attachment in your email.

The manual is 0,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info