2 GOSSEN-METRAWATT
Specifications METRA
Hit
12S ... 16S, 14A
1) TRMS measurement
2) Direct display with clip-on transformer 1000:1
4) At 0 °C...+40°C
5) With zero setting; w/o zero setting + 35 digits
6) With zero setting; w/o zero setting + 50 digits
7) METRAHit 13S (w/o 16 A fuse!): 16 A cont., 20 A for 5 min;
METRAHit 14A, 14S ... 16S: 12 A for 5 min, 16 A 30 s
8) Range 3 V : U
E
= 1.5 V
rms
. . . 100 V
rms
30 V : U
E
= 15 V
rms
. . . 300 V
rms
300 V : U
E
= 150 V
rms
. . . 1000 V
rms
9) On the range 3V , rectangular signal positive at one end 5 ... 15 V, f = const.,
not 163.84 Hz or integer multiple.
10) Without sensor
Meas.
function
Measuring range
Resolution Input impedance
Inherent deviation of the digital display
±(...% of meas. val. +... digits) for reference conditions
Overload capacity
4)
Measuring
function
Overload
value
Overload
duration
METRA
Hit
12S 13S 14A 14S 15S 16S 12S 13S/14A 14S 15S 16S
V
30.00 mV
●●●●
10 µV>10G//<40pF 0.5 + 3
5)
0.5+3
5)
1200 V
DC
AC
effective
sinusoidal
cont.
V
300.0 mV
●●●●
100 µV>10G//<40pF 0.5 + 3 0.5+3
3.000 V
●●●●
1mV 11M //<40pF 0.25 + 1 0.1+1
30.00 V
●●●●
10 mV 10 M//<40pF 0.25 + 1 0.1+1
300.0 V
●●●●
100 mV 10 M//<40pF 0.25 + 1 0.1+1
1000 V
●●●●
1 V 10 M//<40pF 0.35 + 1 0.1+1
V
3.000 V
●●●●
1)
1mV 11M //<40pF
0.75 + 2 (10 ... 300 D)
0.75 + 1 (> 300 D)
0.75 + 3
(> 10 D)
V
30.00 V
●●●●
1)
10 mV 10 M//<40pF
300.0 V
●●●●
1)
100 mV 10 M//<40pF
1000 V
●●●●
1)
1 V 10 M//<40pF
V
3.000 V
1)
1mV 11M //<40pF
0,75 + 3
(> 10 D)
V
30.00 V
1)
10 mV 10 M//<40pF
300.0 V
1)
100 mV 10 M//<40pF
1000 V
1)
1 V 10 M//<40pF
Voltage drop, approx.
12S 13S /14A
14S /
15S/16S
A
300.0 µA
●●
100 nA ——15 mV 1.0 + 5 (> 10 D) 0.5 + 5 (> 10 D)
0.36 A cont.
A
3.000 mA
●●●●
1 µA 15 mV 15 mV 150 mV 1.0 + 5 (> 10 D) 1,0+2 0.5+2
30.00 mA
●●●●
10 µA 150 mV 150 mV 650 mV 0.25 + 2 1.0 + 5 (> 10 D) 0.5 + 5 (> 10 D)
300.0 mA
●●●●
100 µA 1V 1V 1V 1.0 + 2 0,5+2
3.000 A
●●●●
1mA 100 mV 100 mV 1.0 + 5 (> 10 D) 1.0+ 5 (> 10 D)
7) 7)
10.00 A
16A ●●●●
10 mA 300/270mV 270 mV 1.0+2 1.0+2
A
3.000 mA
1 µA ——150 mV 1.5 + 2 (> 10 D)
0.36 A cont.
A
30.00 mA
10 µA 150 mV 150 mV 1.5+ 2 (> 10 D)
300.0 mA
●●
100 µA 1V 1V 1V 1.5 + 2 (> 10 D)
7) 7)
10.00 A
16A ●●
10 mA 300/270mV 270 mV 1.5 + 2 (> 10 D)
A
30.00 A
2)
10 mA 150 mV
1.5+2
(> 10 D)
0.36 A cont.
A
300.0 A
2)
100 mA 1V
A
3.000 mA
1)
1 µA ——150 mV 1.5 + 4 (> 10 D)
A300.0 mA
1)
100 µA ——1V 1.5 + 4 (> 10 D)
12 A 5min
10.00 A
1)
10 mA ——270 mV 1.75 + 4 (>10 D)
No-load voltage
30.00
●●●●
10 m max. 3.2 V 0.5 + 3
5)
0.4+3
5)
500 V
DC
AC
effective
sinusoidal
10 min
300.0
●●●●
100 m max. 3.2 V 0.5 + 3 0.4+3
3.000 k
●●●●
1 max. 1.25 V 0.4 + 1 0.2+1
30.00 k
●●●●
10 max. 1.25 V 0.4 + 1 0.2+1
300.0 k
●●●●
100 max. 1.25 V 0.4 + 1 0.2+1
3.000M
●●●●
1k max. 1.25 V 0.6 + 1 0.4+1
30.00M
●●●●
10 k max. 1.25 V 2.0 + 1 2.0+1
2.000 V
●●●●
1mV max. 3.2 V 0.25 + 1 0.1+1
Discharge
resistance
U
0 max
F
30.00 nF
●●
10 pF 250 k 2.5 V 1.0+3
6)
500 V
DC / AC
effective
sinusoidal
10 min
F
300.0 nF
●●
100 pF 250 k 2.5 V 1.0+3
3.000 µF
●●
1nF 25 k 2.5 V 1.0+3
30.00 µF
●●
10 nF 25 k 2.5 V 3.0+3
Sensor f
min
V f
min
V
Hz
300.0 Hz
●●
0.1 Hz 1 Hz 45 Hz
0.5+1
8)
3 kHz:
1200 V
30 kHz:
300 V
100 kHz:
30 V
cont.
Hz
3.000 kHz
●●
1Hz 1Hz 45Hz
30.00 kHz
●●
10 Hz 10 Hz 45 Hz
100.0 kHz
●●
100 Hz 100 Hz 100 Hz
%
2.0 ... 98.0 %
●●
0.1 % 1 Hz
1 Hz...1 kHz: ±5 D
9)
1 kHz...10 kHz: ±5 D/kHz
9)
%
°C
– 200.0 ...
+ 200.0 °C
●●●●
0.1 °C
Pt 100
2 Kelvin + 5 D
10)
500 V
DC
AC
effective
sinusoidal
10 min
°C
+ 200.0 ...
+ 850.0 °C
●●●●
0.1 °C 1.0+5
10)
– 100.0 ...
+ 200.0 °C
●●●●
0.1 °C
Pt 1000
—— 2 Kelvin + 2 D
10)
+ 200.0 ...
+ 850.0 °C
●●●●
0.1 °C 1.0+2
10)
Analog-digital multimeters
METRA 12S ... 18S, 14A
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAHIT 12S at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAHIT 12S in the language / languages: English as an attachment in your email.

The manual is 0,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info