9 Milliohm Measurement (4-Pole-Measurement)
9.1 Compensation of Cable Resistance
Electrical resistance is a dipole quantity which can generally
only be measured using two poles. This is accomplished by
directing a measuring current of predetermined magnitude
through the device under test, and measuring the resultant
voltage drop. The respective resistance value is derived from
the quotient of these two values.
The two points between which voltage is measured are
decisive as regards the results of the measurement. All
resistances between these two points add to the measured
resistance value. These include contact resistance, as well as
cable resistance. If a very low resistance value needs to be
measured, for example contact resistance at a contactor with
a value of only a few milliohms, the points between which
voltage is measured must be moved out of the measuring
instrument and positioned as closely as possible to the
device under test. For this reason, the measuring instrument
is equipped with separate jacks for current feed and voltage
measurement. This type of 4-pole connection is known as
connection according to Kelvin.
KC4 Kelvin clips and KC27 Kelvin probes (available as
accessories) allow for easy, correct connection.
9.1.1 Measurement with Kelvin Probe KC27
9.2 Thermovoltage Compensation
Thermovoltages which occur as a result of material and
temperature differences may distort measurement results. For
this reason, the instrument is equipped with automatic
thermovoltage compensation in the relevant measuring
ranges.
Note!
If the measuring current is interrupted during 4-wire-
m-measurement or if the fuse is defective, the
message „leads open“ flashes on the display.
If fuse is defective, see chapter 14.2.
VC
m
S+S–
red
black
black
Milliohm measurement on
conductor bars, welds, coils
up to 1 H, etc. with Kelvin
probe KC27 (or Kelvin clip
KC4)
Direct the spring-loaded test
probes inward towards the DUT,
if possible, as they are con-
nected via the red plugs with S
+
or S
(Sense) .
01.180
m
FUNC
MAN
00.010
termoC
m
FUNC
01.170
m
FUNC
m
ZERO
MAN
MAN
Measure
Thermo-
voltage
Thermo-
voltage
Compen-
sated
Measure-
ment
Results
long
30 m
/300 m
at 200 mA
Measuring Ranges:
MAN
FUNC
3 /30 at 20 mA
m
S+S–
VC
R
x
Voltage Drop Measuring Current
m: 0,001 m 30
Overall Measuring Range:
+
Measurement Cables,
KC27 or KC4
Note:
When using KC27 or
KC4 always set red
plug at S
+
or S
,
respectively.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRA HIT H-E CAR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRA HIT H-E CAR in the language / languages: English as an attachment in your email.

The manual is 0,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt METRA HIT H-E CAR

Gossen Metrawatt METRA HIT H-E CAR Quick start guide - English, German, French - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info