6 Saving Minimum and Maximum Values
“MIN/MAX”
with Time Stamp
Minimum and maximum values can be displayed at the
auxiliary displays for long-term observation of measured
quantities.
Ð Press the DATA | CLEAR key twice: Current MIN and MAX
values appear at the auxiliary displays.
Automatic range selection is disabled as long as the
MIN/MAX function is active.
Ð Press the DATA | CLEAR key once again for a display of the
minimum value and the time of its occurrence.
Ð Press the DATA | CLEAR key once again for a display of the
maximum value and the time of its occurrence.
The MIN and MAX values are deleted by pressing and holding
the DATA |CLEAR key (approx. 1 s), by turning the rotary switch,
or by switching the instrument off and back on again.
Note!
No new MIN/MAX values are calculated for a period
of 2 to 4 seconds after the measuring range has been
changed (depending upon measuring function), in
order to allow measured values to settle in.
Function
MIN/MAX
DATA
MIN and MAX
Measured Values /
Time of
Measurement
Response from Instrument
Display
Acoustic
Signal
Main Display
Aux.
Display
1.
Save
2 x short are
saved
Current
measured value
MIN and
MAX
1 x
2.
Save and
Display
short
are
saved
t and
MIN
1 x
short t and
MAX
1 x
3.
Return to 1 short
are
saved
same as 1
same as
1
1 x
Stop
long
are deleted is deleted
is
deleted
2 x
CLEAR
long
MIN
MAX
tMIN
MIN
tMAX
MAX
Current Measured Value
Current Measured Value
Current Measured Value
Current Measured Value
DATA
short
30.000
V
30.000
10.000 data
V
30.000
MIN MAX
10.000 30.000
V
30.000
MIN
09:20:05 10.000
V
30.000
MAX
09:20:05 30.000
V
DATA
DATA
DATA
DATA
MAN
MAN
MAN
blinks
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRA HIT 27I at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRA HIT 27I in the language / languages: English as an attachment in your email.

The manual is 0,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt METRA HIT 27I

Gossen Metrawatt METRA HIT 27I Quick start guide - English, German - 4 pages

Gossen Metrawatt METRA HIT 27I User Manual - Dutch - 28 pages

Gossen Metrawatt METRA HIT 27I Quick start guide - French - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info