4 GMC-I Messtechnik GmbH
1 Safety Features and Precautions
You have selected an instrument which provides you with
high levels of safety.
This instrument fulfills the requirements of the applicable
European and national EC guidelines. We confirm this with
the CE marking. The relevant declaration of conformity can
be obtained from GMC-I Messtechnik GmbH.
The METRA HIT27 is manufactured and tested in
accordance with safety regulations IEC 61010–1:2001 /
DIN EN 61010–1:2001 / VDE 0411–1:2002. When used for
its intended purpose, safety of the operator, as well as that of
the instrument, is assured. Their safety is however not
guaranteed, if the instrument is used improperly or handled
carelessly.
In order to maintain flawless technical safety conditions, and to
assure safe use, it is imperative that you read the operating
instructions thoroughly and carefully before placing your instrument
into service, and that you follow all instructions contained therein.
Observe the following safety precautions:
The instrument may only be operated by persons who
are capable of recognizing contact hazards and taking
the appropriate safety precautions. Contact hazards exist
anywhere, where voltages of greater than 33 V (RMS)
may occur.
Avoid working alone when taking measurements which
involve contact hazards. Be certain that a second person
is present.
Attention!
!
Maximum allowable voltage between any given connector
jack and earth is 600 V, category II.
Attention!
!
Nominal system voltage may not exceed 600 V.
Voltage measurements may only be performed with
the selector switch set to the V or the V~ position.
If the multimeter sockets are confused with the sense
sockets, the instrument may be damaged and the
operator may be subjected to danger!
Attention!
!
Contact hazard!
Dangerous voltages at the external jacks may be
looped through to the sense sockets during voltage
measurement. Therefore do not touch the sense
sockets.
Be prepared for the occurrence of unexpected voltages
at devices under test (e.g. defective devices). For
example, capacitors may be dangerously charged.
Make certain that the measurement cables are in flawless
condition, e.g. no damage to insulation, no interruptions
in cables or plugs etc.
No measurements may be made with this instrument in
electrical circuits with corona discharge (high-voltage).
Special care is required when measurements are made in
HF electrical circuits. Dangerous pulsating voltages may
be present.
Measurements under moist ambient conditions, or with
an instrument with condensation moisture are not
permitted.
Be absolutely certain that the measuring ranges are not
overloaded beyond their allowable capacities. Limit
values are listed in chapter 13 on page 22.
The instrument may only be used in power installations if the
electrical circuit is protected with a fuse or circuit breaker with
a maximum rating of 20 A, and the nominal voltage of the
installation does not exceed 600 V.
Maximum allowable interference voltage between the
jacks (7) and earth briefly amounts to 600 V
RMS
in all
selector switch positions in the event of an error. The fuse
blows at an interference voltage value of > 3 V in the mΩ
range.
Be prepared for the occurrence of unexpected voltages
at devices under test (e.g. defective devices, after testing
coil resistance at contactors etc.), for example,
capacitors may be dangerously charged. In the interest of
safety, always test for the absence of voltage first with
the selector switch in the V and V~ positions.
In order to avoid damage to the instrument when
interference voltages are applied (within allowable limit
values), the mΩ measuring circuit is equipped with an
F1.6A/1000 V fuse, which makes this measuring circuit
highly resistive if excessive current should occur in the
event of a fault for the duration of overloading.
Do not plug the mains power battery charger into the
instrument if normal batteries have been installed instead of
storage batteries.
Warning!
The instrument may not be operated in explosive
atmospheres, or connected to intrinsically safe
electrical circuits.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRA HIT 27I at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRA HIT 27I in the language / languages: English as an attachment in your email.

The manual is 0,51 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt METRA HIT 27I

Gossen Metrawatt METRA HIT 27I Quick start guide - English, German - 4 pages

Gossen Metrawatt METRA HIT 27I User Manual - Dutch - 28 pages

Gossen Metrawatt METRA HIT 27I Quick start guide - French - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info