656044
6
Zoom out
Zoom in
Previous page
1/9
Next page
mask
sec
to.1
speed
Multi
CH
S
%
mask
sec
to.1
speed
Multi
CH
S
%
- 23 - - 24 -
Stable Color Temperature Mode and High-Speed Flash (speed) Mode
Stable Color Temperature Mode or High-Speed Flash (speed) Mode can be chosen in the C.Fn-F1 setting. These
two modes are effective in M/Multi mode and ineffective in high-speed sync mode.
Stable Color Temperature Mode: color temperature ranges within ±200K, which is a good choice for the
photographers who pursues stable color temperature.
High-Speed Flash (speed) Mode: the max flash duration is up to t0.1=1/28984, which is perfect for capturing the
fast-changing actions. As the color temperature is a little higher in this mode, please set the camera’s white balance
parameter to the proportional color temperature amount (see the chart below) or AWB (Auto White Balance).
1/128 5729 1/ 4246 1/128 8835 1/ 28984
1/128+0.3 5718 1/ 4166 1/128+0.3 8808 1/ 26666
1/128+0.7 5686 1/ 3920 1/128+0.7 8810 1/ 24690
1/64 5619 1/ 3920 1/64 8535 1/ 22988
1/64+0.3 5635 1/ 3920 1/64+0.3 8205 1/ 20832
1/64+0.7 5657 1/ 3920 1/64+0.7 7698 1/ 18518
1/32 5630 1/ 3920 1/32 7367 1/ 16666
1/32+0.3 5639 1/ 3920 1/32+0.3 7151 1/ 15150
1/32+0.7 5608 1/ 3702 1/32+0.7 6856 1/ 13332
1/16 5620 1/ 3702 1/16 6579 1/ 11904
1/16+0.3 5647 1/ 3702 1/16+0.3 6440 1/ 10582
1/16+0.7 5657 1/ 3702 1/16+0.7 6216 1/ 8888
1/8 5677 1/ 3702 1/8 6126 1/ 7662
1/8+0.3 5674 1/ 3508 1/8+0.3 6072 1/ 6666
1/8+0.7 5610 1/ 2666 1/8+0.7 5954 1/ 5332
1/4 5568 1/ 2298 1/4 5907 1/ 4596
1/4+0.3 5566 1/ 1904 1/4+0.3 5867 1/ 3808
1/4+0.7 5656 1/ 1626 1/4+0.7 5837 1/ 2898
1/2 5646 1/ 1332 1/2 5844 1/ 2222
1/2+0.3 5681 1/ 1256 1/2+0.3 5738 1/ 1550
1/2+0.7 5649 1/ 832 1/2+0.7 5636 1/ 832
1/1 5549 1/ 316 1/1 5539 1/ 316
SEKONIC C-700
t0.1(S) t0.1(S)
Quicker600IIM Prototype Test
Test Environment Darkroom
Color Temperature
Test
Equipment
Testing Method
Trigger beyond 2 meters and average the amount of 3 tests.
Flash Duration
(t0.1)
IGBT control the time of turning on the ash
Stable Color Temperature Mode High-Speed Flash (speed) Mode
CCT(K)
Level
Parameter
Color
Temperature
Flash Duration
Level
CCT(K)
Parameter
Color
Temperature
Flash Duration
SEKONIC C-700
t0.1(S) t0.1(S)
1/128 5744 1/ 4983 1/128 8823 1/ 35086
1/128+0.3 5759 1/ 4694 1/128+0.3 8877 1/ 33332
1/128+0.7 5747 1/ 4444 1/128+0.7 8930 1/ 30302
1/64 5761 1/ 4444 1/64 8919 1/ 27776
1/64+0.3 5775 1/ 4444 1/64+0.3 8926 1/ 25640
1/64+0.7 5780 1/ 4444 1/64+0.7 8836 1/ 22222
1/32 5753 1/ 4444 1/32 8432 1/ 20202
1/32+0.3 5771 1/ 4444 1/32+0.3 8183 1/ 18518
1/32+0.7 5754 1/ 4444 1/32+0.7 7784 1/ 16666
1/16 5764 1/ 4444 1/16 7368 1/ 15150
1/16+0.3 5752 1/ 4444 1/16+0.3 6983 1/ 13332
1/16+0.7 5755 1/ 4444 1/16+0.7 6763 1/ 11494
1/8 5777 1/ 4444 1/8 6533 1/ 10100
1/8+0.3 5734 1/ 3920 1/8+0.3 6377 1/ 8546
1/8+0.7 5665 1/ 3030 1/8+0.7 6192 1/ 6872
1/4 5604 1/ 2468 1/4 6061 1/ 5648
1/4+0.3 5621 1/ 2468 1/4+0.3 5957 1/ 4566
1/4+0.7 5626 1/ 2222 1/4+0.7 5840 1/ 3508
1/2 5654 1/ 2082 1/2 5962 1/ 2656
1/2+0.3 5672 1/ 1514 1/2+0.3 5807 1/ 2014
1/2+0.7 5695 1/ 1148 1/2+0.7 5711 1/ 1148
1/1 5595 1/ 416 1/1 5579 1/ 416
In this mode, you can set the flash output from 1/1 full power to 1/16th power in 0.3 stop increments.
High Speed Sync enables the flash to synchronize with all camera shutter speeds. This is convenient when you
want to use aperture priority for fill-flash portraits.
Turn the Select Dial to set the
2 flash output power.
Press the <MODE> Button
1 so that < > is displayed.
High-Speed Sync
Please use the transmitter of
3 X1 series.
Quicker400IIM Prototype Test
Test Environment Darkroom
Color Temperature
Test
Equipment
Testing Method
Trigger beyond 2 meters and average the amount of 3 tests.
Flash Duration
(t0.1)
IGBT control the time of turning on the ash
Stable Color Temperature Mode High-Speed Flash (speed) Mode
CCT(K)
Level
Parameter
Color
Temperature
Flash Duration
Level
CCT(K)
Parameter
Color
Temperature
Flash Duration
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Godox Quicker 600 IIM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Godox Quicker 600 IIM in the language / languages: English as an attachment in your email.

The manual is 5,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info