The Buzz Button is used to decide whether there is sound reminder for ready flash after recharging. When the buzz
indicator is displayed on the LCD panel, it means the sound reminder is turned on; if not dislayed, the sound
reminder is turned off.
1. ABI” sound will be heard when it’s fully charged.
2. ABI” sound will be heard when the button and the
select dial echo each other.
mask
sec
to.1
speed
Multi
CH
S
%
mask
sec
to.1
speed
Multi
CH
S
%
mask
sec
to.1
speed
Multi
CH
S
%
mask
sec
to.1
speed
Multi
CH
S
%
mask
sec
to.1
speed
Multi
CH
S
%
mask
sec
to.1
speed
Multi
CH
S
%
- 27 -
- 28 -
Optical S1 Secondary Unit Setting
In M manual flash mode, press <S1/S2> button so that this flash can function as an Optical S1 secondary flash with
Optical sensor. With this function, the flash will fire synchronously when the main flash fires, the same effect as that
by the use of radio triggers. This helps create multiple lighting effects.
Optical S2 Secondary Unit Setting
Press < S1/S2> button so that this flash can also function as an Optical S2 secondary flash with Optical sensor in M
manual flash mode. This is useful when cameras have pre-flash function. With this function, the flash will ignore a
single “preflash” from the main flash and will only fire in response to the second, actual flash from the main unit.
QuickerII has a 150W modeling lamp which offers 5% to 100% light adjustment and 2 long lighting modes.
Modeling Lamp’s ON/OFF and Settings:
1. When the modeling lamp is OFF, short press the Modeling Lamp Button to turn it on;
2. When the modeling lamp is ON, short press the Modeling Lamp Button to setting the light brightness. As the
lighting amount is blinking, turn the Select Dial to choose.
Turn off the Modeling Lamp
Long press the Modeling Lamp Button for 2 seconds to turn it off.
Choose the Modeling Lamp’s Modes
1. Long press the C.Fn Custom Button for 2 seconds until Fn menu is
displayed.
2. Press the SET Button to choose F4.
3. Turn the Select Dial to choose the Modes:
ON: the modeling lamp will keep this status when triggering;
OFF: the modeling lamp will turn off when triggering;
Modeling Lamp
Slave Trigger Model
Buzz Function
C.Fn Setting Custom Function
Long press the C.Fn Custom
1 Button for 2 seconds until
<Fn> menu is displayed.
Press the <SET> Button to
2 choose Fn function signs.
Turn the Select Dial to change
3 the settings. Short press the
C.Fn Custom Button to exit.
Custom
Function
Signs
Function Setting No. Settings & Description Restrictions
F1
Choose high-
speed ash
ON High-Speed Flash (speed) Mode
OFF Stable Color Temperature
F2 Delay ash OFF, 0.01~30S Trigger as second curtain M/Multi mode
F3 Mask function
OFF Mask function is off
M mode
N1
Mask function is on: when setting 2 times’
triggering as a period, the rst triggering will re
a ash.
N2
Mask function is on: when setting 2 times’
triggering as a period, the second triggering will
re a ash.
F4
Modeling lamp
mode
ON
The modeling lamp will not change its status
when triggering.
No
OFF The modeling lamp will turn off when triggering.
M/Multi mode
mask
sec
to.1
speed
Multi
CH
S
%
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Godox Quicker 400 IIM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Godox Quicker 400 IIM in the language / languages: English as an attachment in your email.

The manual is 5,5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info