725132
22
Zoom out
Zoom in
Previous page
1/128
Next page
22
GB
8 Shutting down
8.1 Emptying and cleaning >>
figures
Danger to health due to escaping spraying agents! Pay atten-
tion to the safety instructions in this manual. Observe applicable laws and the specifications
of the agent manufacturers when disposing of residual quantities.
! Activate the pressure relief valve red button until the device is depressurised. The pressure
relief valve may only be activated when the device is in an upright position.
8.2 Maintenance >>
figures
! Observe the national regulations concerning occupational safety which apply to the place of
operation as well as the applicable national regulations for operations. An expert inspection must
be performed ideally by the maintenance service of the manufacturer to establish whether
hazard-free operation remains possible. This should be performed in the event of defects that
may impair safety in particular, and must be performed at least every 5 years in any case.
! Only use original GLORIA spare parts for repairs.
(see GLORIA spare parts shop https://shop.gloriagarten.de).
! Repairs must only be carried out by a GLORIA service point.
! It is forbidden to perform repair work on the container (such as welding and soldering).
! Further accessories can be found at www.gloriagarten.de
8.3 Storage >>
figure
You may be exposed to hazards that could injure you when handling the
device and the spraying pesticides. You must therefore store the device and the spraying
agents out of the reach of children.
!Empty and clean the device as in Chapter 8.1.
9 Problems with the device
28
23
31
29
32
CAUTION
NOTE!
CAUTION
Solvents
Gasoline
Oil
Fault Cause Remedy
Device is leaking at the
screw connection Hose loose Tighten coupling nut
and carry out pressure
test with water
Spray pattern of
nozzle not OK
Nozzle partially blocked
Filter in quick closure valve
contaminated
Clean filter or nozzle
Pump does not build
up any pressure
O-ring on piston is
worn Replace O-ring
RZ_HLSG_Pflanzenschutz_Mehrsprachig.qxp_Text_GB HLSG 06.07.16 19:23 Seite 22
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gloria 505T at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gloria 505T in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 7,72 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info