21
7 Notes regarding the choice of nozzles, dosing and check of nozzles
7.1 Choice of nozzles
7.2 Dosing >>
Spray mixture to be prepared according to the manufacturer’s instructions.
Dosing volume ->
! At first fill in half of the water, then fill in the product and the other half of the water.
After that close the sprayer and shake it.
7.3 Check of nozzles >>
figures
–
Nozzles wear out or clog. Please check at least every two months.
B
Concentration
0,1 % 0,15 % 0,2 % 0,25 % 0,3 % 0,5 % 1,0 % 1,5 %
1 Liter 1 ml 1,5 ml 2 ml 2,5 ml 3 ml 5 ml 10 ml 15 ml
2 Liter 2 ml 3 ml 4 ml 5 ml 6 ml 10 ml 20 ml 30 ml
3 Liter 3 ml 4,5 ml 6 ml 7,5 ml 9 ml 15 ml 30 ml 45 ml
4 Liter 4 ml 6 ml 8 ml 10 ml 12 ml 20 ml 40 ml 60 ml
5 Liter 5 ml 7,5 ml 10 ml 12,5 ml 15 ml 25 ml 50 ml 75 ml
10 Liter 10 ml 15 ml 20 ml 25 ml 30 ml 50 ml 100 ml 150 ml
B
Spray Bore hole or Sprayangle Flow rate Marking Optim. presure Filter
pattern min. clearance in l/min
at pressur/bar
Art. 725830
hollowcone 1 mm 55° 0,42/0,49/0,50/0,60 G-H-49-55 2 bar standard
1,5 / 2,0 / 2,5 / 3,0
Art. 725820
hollowcone 2 mm 80° 1,00/1,16/1,30/1,47 G-H-116-80 2,5 bar special
1,5 / 2,0 / 2,5 / 3,0 acc.
Art. 111.0000
at jet 0,45 mm 80° 0,56/0,65/0,75/0,8 80-02 2,0 bar special
1,5 / 2,0 / 2,5 / 3,0 acc.
A