2 INSTALL WATER LINE
A cold water supply is required for automatic
icemaker operation. The water pressure must
be between 40 and 120 psi.
Route 1/4O.D. copper tubing or GE
SmartConnect
tubing between cold water
line and the water connection location.
Tubing should be long enough to extend to the
front of the refrigerator. Allow enough tubing to
accommodate bend leading into the water line
connection.
NOTE: The only GE approved plastic tubing is
supplied in the GE SmartConnect
Refrigerator
Tubing kits. Do not use any other plastic water
supply line; the line is under pressure at all times.
Certain types of plastic may crack or rupture with
age and cause water damage to your home.
GE SmartConnect
refrigerator tubing kits are
available in the following lengths:
2(0.6m) WX08X10002
6(1.8m) WX08X10006
15(4.6m) WX08X10015
25(7.6m) WX08X10025
Shut off the main water supply.
Turn on the nearest faucet long enough
to purge all the water from the line.
Install a shutoff valve between the icemaker
water valve and cold water pipe in a basement
or cabinet. The shutoff valve should be located
where it will be easily accessible.
NOTE: It is best to install the valve into a vertical
water pipe. If you install the valve into a horizontal
water pipe, make the connection at the top
or side to avoid drawing off any sediment
from the water pipe.
Drill a 1/4 hole in the water pipe.
Fasten the shutoff valve to the pipe with pipe
clamp.
Tighten the clamp screws until the sealing
washer begins to swell. Do not OVERTIGHTEN.
Place a compression nut and ferrule (sleeve) for
copper tubing onto the end of the tubing and
connect it to the shutoff valve. Make sure the
tubing is fully inserted into the valve and ferrule
is tightened.
For plastic tubing from a GE SmartConnect
refrigerator tubing kit, insert the molded end of
the tubing into the shutoff valve and tighten the
compression nut until it is hand tight, and then
tighten an additional turn with a wrench.
Turn on the main water supply and
flush debris. Run about a quart of water
through the tubing into a bucket. Shut
off water supply at the shutoff valve.
NOTE: Saddle type shutoff valves are included in
many water supply kits. Before purchasing, make
sure a saddle type valve complies with your local
plumbing codes.
Floor
Copper Tubing,
or GE SmartConnect
Tubing
Saddle Type
Shutoff Valve
Compression Nut
Ferrule
(Sleeve)
Outlet Valve
Packing Nut
NOTE: Commonwealth of Massachusetts
Plumbing Codes 248CMR must be adhered to.
Saddle valves are illegal and use is not permitted
in Massachusetts. Consult with your licensed
plumber.
Installation Instructions
33
33


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for General Electric 42 Side by side at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of General Electric 42 Side by side in the language / languages: English as an attachment in your email.

The manual is 2,58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info