PROGRAMMING THE ALARM SYSTEM
Has been previously programmed with standard configuration during
manufacturing procedure by Gemini, and can be modified in any moment
With alarm being disarmed, open and keep it open the driver side door.
Turn the ignition "ON".
he status led stay on for 0,5 seconds; during this time, push both the two
buttons of the remote control at the same time.
Starting of programming procedure is indicated by two flashes of the
vehicle indicators.
To activate and de-activate the functions, follow the below table, taking
into consideration that every time the transmitter button is pressed, the
system moves to the next function.
!
!
!
!
!
During the programming phases, press the radio control (rough) push-button
n.1, for function activation and the (smooth) push-button n.2, for function de-
activation.
For the programming modification proceed as follows:
Coninuous or intermittent
siren sound
Double pulse when opening
Panic or boot opening
function
Setting of centralized lock
times (0,5 - 6 sec)
25 seconds comfort closure
command
Power drain must remain
disabled
Anti-distraction, automatic
door locking function
Continuous
Disabled
Disabled
0,5” selected
Disabled
Disabled
Panic function
enabled
Button N°1- Intermittent
N°2-
N°1-
N°2- Enable
N°1-
N°2-
---------
N°2-
Button Continuous
Button Enable 6”
Button 0,5”
Button Enable
Button Disable
Button N°1- Enable
Button N°2- Disable
Button Disable
Button N°1- Enable panic
Button N°2- Enable car-finder
Button N°1- Enable
Button N°2- Disable
FUNCTION STATE BUTTON
NOTE:
Once the last function has been programmed, the alarm will flash the
vehicles indicators and the LED twice confirming the exit of the
programming procedure.
Turn the ignition “OFF”.
!
!
by turning the ignition key to OFF”, the alarm will exit the programming
procedure with all the changes stored.
LEARNING OF NEW CONTROL DEVICES
ATTENTION: in order to carry out successfully the operation, it is
necessary to make the required electrical connections (door switch,
bonnet switch and positive under key).
ATTENTION:
The alarm can save to memory a maximum number of 12 control devices,
either radio controlled, or electronic keys, TAG cards or magnetic contact (the
later as a protection device).
Proceed as follows:
With the alarm being disarmed, open and keep open the bonnet and the
driver side door.
Turn the ignition “ON”.
The alarm will indicate the procedure starting by two slow flashes of the
turn signal; now the alarm is waiting for receiving the device code.
Press the radio control push-button 1, introduce the electronic key in the
specific receptacle, press the TAG card button, make the magnetic contact
to transmit (bring near and then take away contact and magnet) or make the
infrared sensor to transmit (see sensor instructions), according to the
device to be saved to memory.
In all four cases, the alarm will indicate the new device learning, by one led
flashing.
Repeat the procedure to save to memory other devices.
Turn the ignition “OFF”.
The procedure completion will be indicated by one flash of the turn signal.
!
!
!
!
!
!
!
!
!
passive alarm activation must be disabled.
Press a previously learned remote control push-button or insert an already
coded electronic key in the specific receptacle.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gemini 7590T2-1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gemini 7590T2-1 in the language / languages: English as an attachment in your email.

The manual is 0,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info