544618
3
Zoom out
Zoom in
Previous page
1/4
Next page
Description of the appliance
The TCS-Cody consists of a decoder and a keyboard. The units are connected by a simple
double-wire cable without a special plug. Programming of the TCS-Cody is possible with the
keyboard and the master code.
Attendance/Function:
The TCS-Cody 2 has two potential free relay-outputs enabling direct control of a tubular drive
or an industrial door drive unit or similar instruments. After having entered a valid pass code
the user can, within a period of 30 seconds, trigger the installed drive unit in the dead mans
mode with the arrow-keys UP
and DOWN . The relay is activated only as long as the
arrow-keys are pushed. The two relays are interlocked against each other, so it is not possi-
ble that both relays can be attracted at the same time. After expiration of the enable time of
30 seconds the TCS-Cody locks automatically. The appliance can, however, also be blocked
intentionally within the enable time by pushing the key. The enable time is freely pro-
grammable and can be changed according to the individual demands, if required.
Master code:
The master code is an 8-digit numeral code necessary for all programming procedures.
Only after the input of this code the appliance can be programmed according to your
personal needs. TCS-Cody is preset by the company with the master code 12345678.
Pass code:
The pass code is by choice a four- or five-digit numeral code, by which you operate your
door drive unit. You have the possibility to store up to 50 different pass codes, which means
that up to 50 different persons with different pass codes can open the door. In case you
are accompanied by another person when entering your pass code you can at first press
as many keys as you like before you finally enter your code. This ensures that no other
person can notice your pass code, but the TCS-Cody recognizes your pass code as
correct! The TCS-Cody is preset by the company with the pass code 1234 on memory
location 01. The input of a new pass code has always to be finished by pressing .
ATTENTION!!!
After you have made yourself familiar with the functions of the appli
ance, please program your personal master code as well as a pass
code with which you replace the pass code which is located on the
memory place 01. Only by this your TCS-Cody is protected against
manipulation!
Lock-out function:
If the lock-out function is actuated the TCS-Cody automatically blocks for 10 seconds
after the input of a wrong pass code which is signalled with a double sound signal.
By choice, you can arrange that the lock-out time can be doubled after any wrong input
until a correct pass- or master code is entered. The end of the blocking time is signalled
by a long sound signal.
Program 2
Input / Clearing of a pass code
Input 8-digit
master code
Input 4- or 5-digit
pass code
Sound
signal
2 x long
Push
button
Push
button
Input of 2-digit
memory location
e.g. 07 or 28
Sound signal
1 x long
Push
button
The pass code entered is now stored at the memory
location selected and connected to the fixed output !
With this procedure you can allocate 50 different
pass codes to the memory locations 00-49 !!
2
industrial controls
®
industrial controls
®
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Geba Tronic TCS - Cody 2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Geba Tronic TCS - Cody 2 in the language / languages: English as an attachment in your email.

The manual is 0,41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Geba Tronic TCS - Cody 2

Geba Tronic TCS - Cody 2 User Manual - English - 4 pages

Geba Tronic TCS - Cody 2 User Manual - German - 4 pages

Geba Tronic TCS - Cody 2 User Manual - German - 4 pages

Geba Tronic TCS - Cody 2 User Manual - Dutch - 4 pages

Geba Tronic TCS - Cody 2 User Manual - Dutch - 4 pages

Geba Tronic TCS - Cody 2 User Manual - French - 4 pages

Geba Tronic TCS - Cody 2 User Manual - Spanish - 4 pages

Geba Tronic TCS - Cody 2 User Manual - Spanish - 4 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info