3. When Receiving an All-On or All-Off Command
• Parameter 11 (number of steps or levels)
• Parameter 12 (timing of the steps)
• Length: 1 Byte
• Valid Values:
Parameter 11 (default = 1) Valid Values: 1-99
Parameter 12 (default = 3) Valid Values: 1-255
Ignore Start Level When Receiving Dim Commands
Please note: Every “Dim” command includes a start level
embedded in it. The 45639 can be set to ignore the start level
that is part of the dim command. Setting parameter 5 to a value
of 0 will cause the 45639 to dim or brighten from the start level
embedded in the command.
• Parameter No: 5
• Length: 1 Byte
• Valid Values = 0 or 1 (default 1)
Restoring Factory Defaults
All Configuration Parameters can all be restored to their factory default
settings by using your master controller to delete/reset the device.
WARRANTY
JASCO Products warrants this product to be free from manufacturing
defects for a period of two years from the original date of consumer
purchase. This warranty is limited to the repair or replacement of
this product only and does not extend to consequential or incidental
damage to other products that may be used with this product. This
warranty is in lieu of all other warranties, expressed or implied. Some
states do not allow limitations on how long an implied warranty lasts