ADVANCED OPERATION
The following Advanced Operation parameters require that
you have an advanced controller like the GE model 45601 LCD
remote. Advanced remotes from other manufacturers may also
be able to change these settings; however, basic remotes do not
have this capability.
All On/All Off
Depending upon your primary controller, the 45639 switch can
be set to respond to ALL ON and ALL OFF commands in up to four
different ways. Some controllers may not be able to change the
response from its default setting. Please refer to your controller’s
instructions for information on whether or not it supports the
configuration function and if so, how to change this setting.
1. The four possible responses are:
2. It will respond to ALL ON and the ALL OFF command (default).
3. It will not respond to ALL ON or ALL OFF commands.
4. It will respond to the ALL OFF command but will not respond
to the ALL ON command.
5. It will respond to the ALL ON command but will not respond to
the ALL OFF command.
LED
When shipped from the factory, the LED is set to turn ON when
the connected light is turned OFF. This is the default setting and
can be changed if your primary controller supports the node
configuration function. To make the LED turn ON when the light is
turned ON, change parameter 3’s value to “1”. To turn the LED OFF
at all times, change parameter 3’s value to 2.
• Parameter No: 3
• Length: 1 Byte