IGNITION LEAD
Follow the Pilot Unit instruction to access the back of the pilot
assembly.
Disconnect the ignition lead from the electrode.
Remove the front cover from the control valve by removing
the retaining screw and gently levering clear with at bladed
screwdriver.
NOTE: There is a small cylindrical metal spacer inside the
cover, this must be kept and replaced on the xing screw on
re-assembly.
Disconnect the other end of the ignition lead from the valve body
noting the route of the ignition lead.
Replace with a new ignition lead following the same route as the
old one.
Replace the valve cover and the pilot assembly.
Check operation of the new ignition lead.
PIEZO
The piezo assembly used on this appliance is not serviceable and
is not likely to fail.
If a new piezo is required it will be necessary to change the valve.
PRIMARY AERATION PLATE
NOTE: Not all models have aeration plates.
Please refer to the Technical Specication.
To replace the primary aeration plate turn off the gas supply at the
isolation device.
Remove the burner.
Undo the 2 nuts and remove the plate.
Replace with the correct size plate and secure the 2 nuts. Ensure
that the lower edge of the plate is located over the venturi ange.
MAIN INJECTOR
To remove the main injector turn off the gas supply at the isolation
device.
Remove the main burner.
Undo the compression nuts from the feed pipe and the gas
valve under the appliance.
Working from inside the rebox remove the lock nut from the
injector.
Extract the injector with the feed pipe from beneath the appliance.
Holding the injector with a spanner:
Undo the feed pipe. Note the orientation of the Injector.
Re-assemble in reverse order.
Turn on the gas supply and check for leaks.
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Vogue Range Balanced Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Vogue Range Balanced Flue in the language / languages: English as an attachment in your email.

The manual is 8.41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info