813425
19
Zoom out
Zoom in
Previous page
1/52
Next page
19
TOP FLUE UP AND OUT WITH
ADDITIONAL BEND
An additional bend can be used on the horizontal section (45° or
90°) but the overall horizontal ue is reduced.
When A = 1.0 to 1.499 metres B+C = 1.0 metre max (Nat Gas - No restrictor,
LPG - 75mm Restrictor)
When A = 1.499 to 3.0 metres B+C = 4.0 metres max (Nat Gas - 70mm restrictor,
LPG - No restrictor)
EITHER 45˚
OR 90˚
TOP FLUE VERTICAL KIT
This ue is vertical from the top of the appliance, see Diagram right.
A minimum vertical rise of 3m to a maximum of 10m.
999-539/999-539AN - VOGUE MIDI/ MIDLINE MODELS
The basic kit comprises:
2 x 1m lengths
1 x 1m terminal lengths
1 x 52mm restrictor (sliding plate assembly)
1 x 47mm restrictor (sliding plate assembly)
8524/8524AN - VOGUE MIDI/ MIDLINE/ HIGHLINE T MODELS
The basic kit comprises:
2 x 1m lengths
1 x 1m terminal length
1 x 52mm restrictor
1 x 47mm restrictor
1 x 60mm restrictor - Not used on this appliance
1 x 70mm restrictor - Not used on this appliance
ALL MODELS
Extra lengths can be added.
Refer to Technical Specication to identify when to use a restrictor.
TOP FLUE VERTICAL OFFSET KIT
8530/8530AN
Used with kits 999-539 and 8524. A minimum rise of 500mm is
required to the rst bend, see Diagram.
OPTIONAL EXTRA FLUE LENGTHS
AND BENDS
NOMINAL
LENGTH
ACTUAL
LENGTH
STAINLESS
FINISH
ANTHRACITE
FINISH
200mm 140mm 8527 8527AN
500mm 440mm 8528 8528AN
1000mm 940mm 8529 8529AN
45° Bend N/A 8507 8507AN
90° Bend N/A 8508 8508AN
Optional Flue Collar 8548MB
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Vogue Range Balanced Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Vogue Range Balanced Flue in the language / languages: English as an attachment in your email.

The manual is 8.41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info