SITE REQUIREMENTS
REAR FLUE
This ue extends horizontally from the back of the appliance.
ALL MODELS (8526)
200mm min
550mm max
Terminal dimensions:
395 x 200 x 200 mm (H x W x D)
Guard supplied
Cut to length as required on site.
TOP FLUE
There are two types of ue terminal: Horizontal and Vertical.
FOR HORIZONTAL TERMINAL
INSTALLATIONS:
Decide on the terminal position.
Measure the height from the top of the appliance to the centre of the
required hole. For minimum and maximum dimensions see all Up
and Out Diagrams.
To t the ue access is required to the top or the side of the
appliance to connect the ue.
Assemble the vertical sections making sure the top plate and ue
collar are tted before the ue pipe.
Add the 90° elbow.
Add the horizontal section and terminal.
Only the horizontal terminal can be reduced in size.
A masonry installation requires the addition of a suitable lintel to
support the opening. Refer to Technical Information for details of the
ue length
TOP FLUE UP AND OUT KIT
This ue rises vertically from the top of the appliance, then
continues horizontally outward.
The basic kit comprises:
ALL MODELS (8523/8523AN)
1 x 500mm vertical length
1 x 500mm terminal length
1 x 90 degree elbow
1 x wall plate
1 x 52mm restrictor
1 x 60mm restrictor
1 x 75mm restrictor
4 x xing screw
Vogue Midi/ Midline
Vogue Midi T/ Midline/ Highline
This kit provides the minimum materials. Extra lengths can be
added to the vertical and horizontal sections.
Refer to Technical Specication to identify when to use a restrictor.
18


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Vogue Range Balanced Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Vogue Range Balanced Flue in the language / languages: English as an attachment in your email.

The manual is 8.41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info