813416
17
Zoom out
Zoom in
Previous page
1/36
Next page
17
Installation Instructions
3.6 Support the opening of a masonry installation with a lintel.
3.7 Only the horizontal terminal section can be reduced in size.
To find the length:
3.8 Measure from the outside of the wall to the stop on the 90°.
3.9 Add 10mm to the outlet end.
3.10 Measure from the edge of the slots closest to the wall.
3.11 Mark around the flue, see Diagram 10.
10
10mm
A wall plate is supplied to fix the flue to the wall:
3.12 Bend the tab to 90°.
3.13 Assemble the plate onto the flue but wait to secure to wall
and flue after the flue is fully assembled, see Diagram 10.
3.14 The cardboard fitment in the terminal is used to support the
flue whilst it is cut to length. ONCE CUT TO SIZE, REMOVE
THE CARDBOARD REMNANT, see Diagram 11.
11
3.15 PURGE THE SUPPLY PIPE. This is essential to expel any
debris that may block the gas controls.
3.16 Connect the gas to the 8mm elbow on the rear of the
appliance.
12
3.17 Connect a suitable pressure gauge to the test point located
on the inlet fitting.
3.18 Turn on the gas.
3.19 Light the appliance and check for leaks.
3.20 Turn the appliance to maximum and check that the supply
pressure is as stated on the data badge.
3.21 Turn off the gas and replace the test point screw.
3.22 Turn the gas back on and check the test point for leaks.
4. Assembling the Appliance
4.1 The Vision appliances have the option of 3 different liner
finishes:
Vermiculite
Black Reeded Panels
Black Glass Linings
Vermiculite & Black Reeded
NOTE: ALL FRONT PANELS ARE IN TWO PIECES.
HOLD THE REAR PANELS UNTIL ALL THE OTHER
PANELS ARE IN PLACE AS THEY CAN FALL FORWARD.
4.2 Place the rear panel(s) behind the locating bracket on the
rear support bar.
4.3 Centralise the rear panel(s) with the chamfers touching and
pushed together, see Diagram 13.
13
Rear Support Bar
Rear Panel(s)
4.4 Place the lower side and front panels in position so the
chamfers meet at the front edge of the burner.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Vision Large MK2 Series Balanced Flue Instructions at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Vision Large MK2 Series Balanced Flue Instructions in the language / languages: English as an attachment in your email.

The manual is 4.65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info