813413
40
Zoom out
Zoom in
Previous page
1/48
Next page
40
Servicing Instructions - Replacing Parts
12.6 After replacing the control box you may need to reprogram
the handset.
— Press and hold the reset button on the control box until
you hear two signals. After the second longer signal:
— Release the reset button and within 20 seconds:
— Press the DOWN button on the handset until you hear 2
additional short signals conrming the new code is set.
If there is a single long signal the code learning
sequence has failed or the wiring is incorrect.
13. Main Injector
To change the main injector:
13.1 Undo the injector feed pipe.
13.2 Undo the lock nut from the injector and remove the
silencer.
13.3 Replace with the correct size injector.
13.4 Check for leaks.
14. Primary Aeration Plate
NOT ALL MODELS HAVE AERATION PLATES. REFER
TO TECHNICAL SPECIFICATIONS, PAGES 9.
14.1 Remove the burner module as described in Replacing Parts
Section 6.
14.2 Remove the xing screw and slide the plate off the venturi.
14.3 Replace with the correct size plate and secure with the
screw. Ensure the lower edge of the plate is located over
the venturi ange, see Diagram 23.
23
15. Changing Between Gas Types
A kit of parts is available for this - Contact your Gazco
retailer for further information.
Always quote the Model number and Serial number when
ordering any spare parts.
16. Pressure and leak testing
the appliance
16.1 Follow Section 7, Main Control Assembly.
16.2 Access to the pressure test point can now be reached,
see Diagram 24.
24
16.3 Refer to Installation Instructions, Section 3 to check gas
pressure.
16.4 Light the appliance and spray any joints with leak detector
uid.
16.5 Tighten joints or replace as required.
16.6 To check the inlet working pressure, replace the control
assembly and connect a manometer to the pressure test
point, see Diagram 24. Replace the burner and relight the
appliance. Operate the appliance at highest ame setting
and check that the inlet pressure is in accordance with
specications detailed on page 9.
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Studio Freestanding Conventional Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Studio Freestanding Conventional Flue in the language / languages: English as an attachment in your email.

The manual is 8.4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info