1. Safety Precautions
1.1 For your own and other’s safety, you must install this
appliance according to local and national codes of practice.
Failure to install the appliance correctly could lead to
prosecution. Read these instructions before installing
and using this appliance.
1.2 These instructions must be left intact with the user.
1.3 Do not attempt to burn rubbish on this appliance.
1.4 Keep all plastic bags away from young children.
1.5 Do not place any object on or near to the appliance and
allow adequate clearance above the appliance.
IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT
IN USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO
RELIGHT THE APPLIANCE.
1.6 The appliance is fitted with the Gazco Flue Sure System,
which will act to cut off the gas supply to the burners in the
event of incorrect operation of the flue. If the system acts to
cut off the gas supply, this indicates that there is insufficient
flue pull. If this occurs a minimum of 10 minutes should be
allowed before trying to relight. Continued operation of this
safety device means there may be a serious problem with
the flue system. A qualified GasSafe engineer should
inspect this.
1.7 Do not alter or tamper with the Flue Sure System. Use only
genuine Gazco replacement parts when servicing the
system - refer to the Servicing Section, Replacing Parts.
DO NOT USE THE APPLIANCE UNTIL AN ENGINEER
SAYS IT IS SAFE TO DO SO.
IMPORTANT: REFER TO DATA BADGE AND
TECHNICAL SPECIFICATION AT THE FRONT OF
THE MANUAL TO ENSURE THE APPLIANCE IS
CORRECTLY ADJUSTED FOR THE GAS TYPE
AND CATEGORY APPLICABLE IN THE COUNTRY
OF USE.
FOR DETAILS OF CHANGING BETWEEN GAS
TYPES REFER TO SERVICING, SECTION 12,
REPLACING PARTS.
Unpacking
1.8 Remove the appliance from its packaging, and check that it
is complete and undamaged.
2. Upgrading the Appliance
2.1 The appliance is fitted with a control valve that can easily be
upgraded to battery powered remote control.
There are two versions of this control which can be obtained
through your local Gazco retailer.
There is no requirement for this upgrade to be carried out by
an approved GasSafe engineer. However Gazco recommend
that this task is undertaken by a suitably competent person.
2.2 This upgrade can be fitted before or after installation but if
side clearances are limited then it will be easier to upgrade
the appliance before installation. Full instructions are
included with the kit.
Standard Remote Control
(PART NUMBER 8455)
2.3 This remote control can control the gas appliance after
the pilot has been lit. It can turn the main burner on and
regulate it from low through to high and back again.
It can turn the main burner off leaving the pilot burning.
Thermostatic and Timer Remote Control
(PART NUMBER 8456)
2.4 This remote control can control the gas appliance after the
pilot has been lit.
MANUAL MODE
Can be used to turn the main burner on and manually
regulate it from low through to high and back again. It can
also be used to turn the main burner off leaving the pilot
burning.
AUTO MODE
Will automatically regulate the room to a pre-set temperature.
TIMER MODE
Will turn the appliance on and off according to a pre-set
programme and automatically regulate the room temperature
during the two on periods.
Installation Instructions
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Steel Manhattan Log Conventional at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Steel Manhattan Log Conventional in the language / languages: English as an attachment in your email.

The manual is 2.32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info