1. Flue & Chimney Requirements
1.1 The chimney or flue system must comply with the rules in
force, and must be a minimum of 127mm in diameter. (5").
1.2 The minimum flue height for the appliance must be 3 metres
(10ft). Any horizontal flue run from the rear outlet must not
exceed 100mm from the back of the appliance.
1.3 The chimney or flue must be free from any obstruction. Any
damper plates must be removed or secured in the fully open
position, and no restrictor plates fitted.
1.4 The chimney must be swept prior to the installation, but it
need not be swept if it can be seen the chimney is clean and
unobstructed throughout its entire length.
NOTE: If it is intended to fit the stove into an existing
brick- built chimney a 5" (127mm) liner must be used.
Larger lined flues may work, but in some instances
could cause cold start flue problems resulting in
nuisance shutdown. Lined flues above 7" (175mm) are
not recommended.
The European chimney standards now describe chimneys
and flues by their temperature, pressure and resistance to
corrosion, condensation and fire. To identify the correct flue
system, the minimum flue specification is shown in the
Technical Specification. Existing chimneys are not covered
by this system.
2. Gas Supply
THIS APPLIANCE IS INTENDED FOR USE ON A GAS
INSTALLATION WITH A GOVERNED METER.
2.1 Before installation, ensure that the local distribution
conditions (identification of the type of gas and pressure)
and the adjustment of the appliance are compatible.
2.2 Ensure the gas supply delivers the required amount of gas
and is in accordance with the rules in force.
2.3 Soft copper tubing and soft soldered joints can be used but
must not be closer than 50mm to the base of the tray.
2.4 A means of isolating the gas supply to the appliance must
be provided independent of any appliance control.
2.5 All supply gas pipes must be purged of any debris that may
have entered prior to connection to the appliance.
2.6 The gas supply must be installed in a way that does not
restrict the removal of the appliance for servicing and
inspection.
Installation Instructions
Site Requirements
3. Ventilation
IMPORTANT: Ensure any national ventilation
requirements are taken into account during installation
of the appliance.
3.1 This appliance has a nominal input not exceeding 7.0kw and
therefore, does not normally require any additional
permanent ventilation.
3.2 If however, spillage is detected when commissioning the
appliance, there may be insufficient natural ventilation and
additional ventilation may be required.
FOR THE REPUBLIC OF IRELAND REFER TO THE
RULES IN FORCE FOR VENTILATION REQUIREMENTS.
4. Appliance Location
4.1 Building Regulations state this appliance must stand on a
non-combustible hearth that is at least 12mm thick and
projects 50mm minimum from the base of the appliance in
all directions, however Gazco recommend the hearth
extends to the following dimensions, see Diagram 1.
C
A
B
1
A = 1009mm
B = 525mm
C = 12mm
4.2 Do not install in a room that contains a bath or shower.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Steel Manhattan Log Conventional at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Steel Manhattan Log Conventional in the language / languages: English as an attachment in your email.

The manual is 2.32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info