Model
Steel Manhattan
CF NG
Steel Manhattan
CF LPG
Fuel
Space Heating Emissions (NOx) - mg / kWh input (GCV) 130 130
Heat
Output
Nominal Heat Output - Pnom 4.5kW 4.5kW
Minimum Heat Output (indicative) - Pmin 2.0kW 2.0kW
Auxiliary
Electricity
Consumption
At Nominal Heat Output - elmax N/A N/A
At Minimum Heat Output - elmin N/A N/A
In Standby Mode - elsb N/A N/A
Useful
Efciency
(NCV)
Useful Efciency at nominal heat output - ηth,nom 78.0% 78.0%
Useful Efciency at minimum heat output (indicative) - ηth,min 68.0% 68.0%
Permanent
Pilot Flame
Power
requirement
Permanent Pilot Flame Power requirement (if applicable) - Ppilot 0.200kW 0.200kW
Type of heat output/room temperature control
Two or more manual stages, no room temperature control Yes Yes
Other control options (multiple selections possible)
Room temperature control, with presence detection No No
Room temperature control, with open window detection No No
With distance control option No No
With adaptive start control No No
With working time limitation No No
With black bulb sensor No No
Model with Manual Control
Energy Efciency Index 66.8% 66.8%
Energy Efciency Class E E
Model with upgradeable Thermostatic controls
Type of heat output/room temperature control
Electronic room temperature control + day timer Yes Yes
Energy Efciency Index 71.8% 71.8%
Energy Efciency Class E E
Contact: Gazco Ltd, Osprey Road, Sowton Industrial estate, Exeter, EX2 7JG
Information Requirement for Gaseous Fuel Local Space Heater
Information Requirement - Gas Heaters
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Steel Manhattan Coal Conventional at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Steel Manhattan Coal Conventional in the language / languages: English as an attachment in your email.

The manual is 2.07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info