8. Magnetic Safety Valve
8.1 Turn the gas supply off at the isolation device.
8.2 Undo the thermocouple connection from the back of the gas
valve.
8.3 Undo the magnetic valve retaining nut at the back of the
control valve, see Diagram 14, Arrow A.
8.4 Gently tap out the magnetic valve and replace with a new
unit.
8.5 Replace the retaining nut and tighten.
8.6 Secure the thermocouple in the rear of the gas control. (Do
not over tighten).
8.7 Turn the gas supply on and check the entire pipe work and
valve joints for any leaks.
9. Main Injector
9.1 Turn the gas supply off at the isolation device.
9.2 Remove the main burner, see Section 3.
9.3 Undo the compression nut from the feed pipe at the gas
control under the appliance.
9.4 Working from inside the firebox, remove the lock nut from
the injector, see Diagram 15.
15
9.5 Extract the injector with the feed pipe from beneath the
appliance.
9.6 Holding the injector with a spanner, undo the feed pipe.
NOTE: THE ORIENTATION OF THE INJECTOR.
9.7 Reassemble in reverse order,
9.8 Turn on the gas supply and check for any leaks.
Servicing Instructions - Replacing Parts
10. Primary Aeration Plate
10.1 Turn the gas supply off at the isolation device.
10.2 Remove the main burner, see Section 3.
10.3 Remove the 2 screws on the burner skin to detach the
venturi cover from the venturi. Slide the venturi cover off the
venturi, see Diagram 16.
16
10.4 Refer to the technical specification and databadge to check
the gas type and its required aeration plate. Change the
aeration plate, if necessary.
17
10.5 Reassemble in reverse order with correct aeration plate(s).
Note: Even if no aeration plate is required, the small
screw(s) must be replaced.
11. Changing Between Gas Types
A kit of parts is available for this - Contact your Gazco
retailer for further information.
Always quote the Model number and Serial number when
ordering any spare parts.
12. Control Upgrade
See Installation Instructions, Section 2.
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Steel Manhattan Balanced Log at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Steel Manhattan Balanced Log in the language / languages: English as an attachment in your email.

The manual is 2.45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info