813479
4
Zoom out
Zoom in
Previous page
1/52
Next page
4
GENERAL
Installation and servicing must only be carried out by a competent
person whose name appears on the GasSafe register. To ensure
the engineer is registered with GasSafe they should possess an ID
Card carrying the following logo:
In all correspondence, please quote the appliance type and serial
number which can be found on the data badge located at the rear
of the appliance or on the Commissioning Checklist on Page 3.
Do not place curtains above the appliance:
You must have 300mm clearance between the appliance and any
curtains at either side.
The manufacturer considers the full outer casing of this stove to
be a working surface and it will become hot whilst in operation. A
suitable guard is recommended to protect young children, the aged
and the inrm.
No furnishings or other objects should be placed within
1 metre of the front of the appliance.
If a shelf is fitted, a distance of 225mm above the appliance is
required.
Do not attempt to burn rubbish in this appliance.
This appliance must only be operated with the door secured rmly
in position. If any cracks appear in the glass the appliance must not
be used until the glass panel is replaced.
If, for any reason, the ue has to be removed from the appliance,
the seals must be replaced in the inner spigot.
Do not obstruct the ue terminal in any way i.e. by planting owers,
trees shrubs etc. in the near vicinity, or by leaning objects up
against the terminal guard.
Do not put any objects on the terminal guard; it will lose its shape.
Do not use a garden sprinkler or hose near the terminal.
This product is guaranteed for 5 years from the date of installation,
as set out in the terms and conditions of sale between Gazco and
your local Gazco retailer. Please consult with your local Gazco
retailer if you have any questions. In all correspondence always
quote the Model Number and Serial Number.
OPERATING THE APPLIANCE
There are two ways of lighting the appliance:
Using the Manual Controls on the Control Box
(located on the appliance).
By Thermostatic Remote Control.
MANUAL OPERATION (CONTROL BOX)
Power Switch
Power Button
Flame Adjustment (Up)
Flame Adjustment (Down)
To operate the appliance the Power Switch on the Control Box
must be switched ON ( l ).
Note: The Power Switch does not need to be turned
off each time the appliance is not in use.
However, if the appliance is left unattended for long
periods of time (e.g. vacation), it is recommended to
place the Power Switch into the off position.
TURNING THE APPLIANCE ON:
Press and hold the Power Button for 1 second and release.
The burner will light approximately 2 to 3 seconds later.
Use + and - buttons to adjust the flame height between Minimum
and Maximum.
TURNING THE APPLIANCE OFF
Press the power button to turn the appliance off.
IMPORTANT: YELLOW FLAMES TYPICALLY
APPEAR WHEN THE APPLIANCE HAS REACHED
NORMAL OPERATING TEMPERATURE. THIS CAN
TAKE UP TO 30 MINUTES.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Sheraton 5 - Balanced Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Sheraton 5 - Balanced Flue in the language / languages: English as an attachment in your email.

The manual is 8.83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info