Servicing Instructions - Replacing Parts
8.5 Disconnect the battery extension lead, Diagram 14, B
The control assembly can now be lifted up and removed.
8.6 Reassemble in reverse order.
9. Pilot Unit Assembly
9.1 Remove the screw retaining the pilot cover.
15
9.2 Cut the cable tie retaining the vida flex sleeve and
disconnect the ignition lead from the electrode.
4.0mm
16
13mm
9.3 Undo the pilot pipe and thermocouple from the rear of valve.
9.4 Remove the two fixing screws and retain the vida flex sleeve
which is needed for the replacement.
9.5 Replace in reverse order.
9.6 Ensure the thermocouple and ignition lead are threaded
through the vida flex and secured with a cable tie. There is a
cut out in the pilot shroud to hold the vida flex.
9.7 Check for gas leaks.
10. Ignition Lead
10.1 Cut the cable tie securing the vida flex (if present) and
disconnect the ignition lead from the electrode.
10.2 Pull the lead through the vida flex.
10.3 If necessary cut any cable ties and disconnect the lead from
the control box, see Diagram 17.
17
10.4 Replace in reverse order.
10.5 Ensure the lead is passed through the vida flex, secured
with a cable tie and the red insulated end is attached to the
electrode.
NOTE: DO NOT ROUTE THE IGNITION LEAD IN
THE VICINITY OF THE ANTENNA ON THE
CONTROL BOX. THIS DAMAGES THE
COMPONENTS.
11. Gas Valve
To change the gas valve:
11.1 Disconnect the gas inlet pipe, Diagram 18, Arrow A.
11.2 Disconnect the gas outlet pipe, Diagram 18, Arrow B.
11.3 Disconnect the pilot pipe, Diagram 18, Arrow C.
11.4 Disconnect the thermocouple, thermo current wires and the
interrupter block, Diagram 18, Arrow D
11.5 Remove the two screws and rotate the valve to access the
front.
11.6 The cable can now be removed from the valve, Diagram 18
Arrow E.
C
D
A
B
E
18
Replace in reverse order ensuring and check for leaks.
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco riva Vision Large Conventional Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco riva Vision Large Conventional Flue in the language / languages: English as an attachment in your email.

The manual is 3.5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info