Installation Instructions
1. Flue & Chimney Requirements
WHEN INSTALLING A FLUE SYSTEM PLEASE REFER
TO THE MANUFACTURER’S INSTRUCTIONS.
The European chimney standards now describe chimneys
and flues by their temperature, pressure and resistance to
corrosion, condensation and fire. To identify the correct flue
system, the minimum flue specification is shown in the
Technical Specification. Existing chimneys are not covered
by this system.
The flue must be installed in accordance with all local and
national regulations and the current rules in force:
1.1 A flexible liner must be continuous from the appliance spigot
to the roof terminal.
1.2 The minimum effective height of the flue must be 3m (10').
1.3 The flue must be free from any obstruction.
1.4 Any damper plates must be removed or secured in the fully
open position and no restrictor plates fitted.
1.5 The chimney should be swept immediately before installing
the appliance, but it need not be swept if you can see the
chimney is clean and free from obstruction throughout.
2. Flue Options
Top Exit only - Twin Wall Rigid
127mm (5”)
A range of Vitreous Enamel Gloss Black flue pipe is
available to compliment the Riva Vision. Please contact
your Gazco retailer for further information.
3. Gas Supply
This appliance is intended for use on a gas installation
with a governed meter.
3.1 Make sure local distribution conditions (identification of the
type of gas and pressure) and the adjustment of the
appliance are compatible before installation.
3.2 Ensure the gas supply delivers the required amount of gas
and is in accordance with the rules in force.
3.3 Soft copper tubing can be used on the installation and soft
soldered joints outside the appliance and below the firebed.
3.4 A factory fitted isolation device is part of the inlet connection;
no further isolation device is required.
3.5 All supply gas pipes must be purged of any debris that may
have entered prior to connection to the appliance.
3.6 The gas supply enters through the silicone panel located on
the LEFT-HAND side of the outer box. Slit with a sharp knife
prior to passing the supply pipe through.
3.7 The gas supply must be installed in a way that does not
restrict the removal of the appliance for servicing and
inspection.
4. Ventilation
IMPORTANT: Ensure any national ventilation
requirements are taken into account during installation
of the appliance.
UK ONLY:
The Riva Vision has a nominal input not exceeding 7.0kW
and does not normally require any additional permanent
ventilation.
If however, spillage is detected when commissioning the
appliance, there may be insufficient natural ventilation and
additional ventilation may be required.
FOR THE REPUBLIC OF IRELAND REFER TO THE
RULES IN FORCE FOR VENTILATION REQUIREMENTS.
5. Appliance Location
5.1 This appliance has been designed to stand on either a
hearth or an optional bench:
RVACLB100B - Riva Bench Low (100cm wide)
RVACB100B - Riva Bench (100cm wide)
RVACLB120B - Riva Bench Low (120cm wide)
RVACB120B - Riva Bench (120cm wide)
RVACLB140B - Riva Bench Low (140cm wide)
RVACB140B - Riva Bench (140cm wide)
5.2 To install the bench:
Follow Section 1, Installation - All Models in the installation
guide (PM205) supplied with the bench kit.
5.3 To secure the appliance to the bench:
You must consider where you place the appliance on the
bench before using the template, see Diagram 1.
1
Site Requirements
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco riva Vision Large 50000 series Conventional Flue Instructions at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco riva Vision Large 50000 series Conventional Flue Instructions in the language / languages: English as an attachment in your email.

The manual is 2.97 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info