HEADING
8. MAIN INJECTOR
8.1 Remove the burner module as described in Servicing,
Section 2. Disconnect the pipe from the injector and the
gas valve (see Diagram 19).
19
AR0825
8.2 Rotate the injector until it is fully removed, and install the
correct replacement injector. Re-assemble and turn the gas
supply on, check for any leaks.
9. PRIMARY AERATION PLATE
NOT ALL MODELS HAVE AERATION PLATES. REFER TO
TECHNICAL SPECIFICATIONS, PAGE 10.
9.1 Remove the burner module as described in Servicing,
Section 2.
9.2 Remove the fixing screw and slide the plate off the venturi.
9.3 Replace with the correct size plate and secure with the
screw. Ensure the lower edge of the plate is located over
the venturi flange (see Diagram 20).
20
AR0766
SERVICING INSTRUCTIONS
REPLACING PARTS
10. CHANGING BETWEEN GAS TYPES
In order to change between gas types, it will be necessary to
change the following items:
Burner Unit
Pilot Injector
Control Valve
Injector
Aeration Plate (if required)
Data Badge
A kit of parts is available for this, always quote the Model
number and Serial number when ordering any spare parts.
NOTE: THE CONTROL VALVE IS FACTORY PRESET FOR
THE CORRECT GAS TYPE AND MODEL, A NEW UNIT
WILL NEED TO BE ORDERED WHEN CHANGING
BETWEEN GAS TYPES.
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Riva Nemos Coprecci at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Riva Nemos Coprecci in the language / languages: English as an attachment in your email.

The manual is 3.17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info