813405
35
Zoom out
Zoom in
Previous page
1/40
Next page
35
SERVICING INSTRUCTIONS
REPLACING PARTS - BALANCED FLUE
5.3 Disconnect the external pilot pipe from the brass fitting
(see Diagram 13, arrow A).
13
A
AR0822a AR2587
Riva 67
B
5.4 Remove the external inlet pipe from the brass fitting (see
Diagram 13 arrow B).
5.5 Remove the control box undoing the 2 x screws securing it
to the base of the appliance (see Diagram 14).
14
AR2587
Screws
5.6 The whole bracket containing the valve control and battery
box should now be able to slide out allowing removal of the
pipes and thermocouple.
5.7 Undo the 2 x 7mm nuts securing the valve to the bracket.
5.8 Replace in reverse order.
5.9 Check all joints for gas leaks, check the operation of the
thermocouple and ignition lead.
6. MAGNETIC SAFETY VALVE
6.1 Remove the gas valve as described in Section 5.
6.2 Undo the magnetic valve retaining nut at the back of the
control valve. Gently tap out the mag valve and replace
with a new unit (see Diagram 16). Replace in reverse order.
15
AR2590
Retaining nut
7. MAIN INJECTOR
7.1 Remove the burner module as described in Servicing,
Section 2. Disconnect the pipe from the injector and the
gas valve (see Diagram 16).
16
AR0825
7.2 Rotate the injector until it is fully removed, and install the
correct replacement injector. Re-assemble and turn the gas
supply on, check for any leaks.
8. PRIMARY AERATION PLATE
NOT ALL MODELS HAVE AERATION PLATES. REFER TO
TECHNICAL SPECIFICATIONS, PAGE 10.
8.1 Remove the burner module as described in Servicing,
Section 2.
8.2 Remove the fixing screw and slide the plate off the venturi.
8.3 Replace with the correct size plate and secure with the
screw. Ensure the lower edge of the plate is located over
the venturi flange (see Diagram 17).
35


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Riva F67 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Riva F67 in the language / languages: English as an attachment in your email.

The manual is 4.73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info