6. Removal & Fitting of the Liners
6.1 The Riva2 appliance comes with four optional liner finishes:
Vermiculite
Black Reeded
Brick Effect
Black Glass - see separate instructions PR2214 for details.
6.2 To fit the desired liner type remove the retaining bracket at
the top rear of the firebox, see Diagram 7.
7
Retaining Bracket
Screws
6.3 Slide the back liner panel over the bracket in the base of the
firebox and stand upright against the back of the appliance,
see Diagram 8.
8
Bracket Liner
6.4 Replace the top retaining bracket to hold the back panel in
place.
6.5 Slide the two side liners into place between the side of the
firebox and the burner tray, see Diagram 9.
9
To replace the decorative front:
5.12 Rest the bottom fixing hooks into the bottom locating slots.
Lift the upper frame fixing hooks into the top locating slots
and lower into final position, see Diagram 6.
6
Advice on handling and disposal
of fire ceramics
The side panels in this appliance are made from
Refractory Ceramic Fibre (RCF), a material which
is commonly used for this application.
Protective clothing is not required when handling
these articles, but we recommend you follow
normal hygiene rules of not smoking, eating or
drinking in the work area and always wash your
hands before eating or drinking.
To ensure that the release of RCF fibres are kept to
a minimum, during installation and servicing a
HEPA filtered vacuum is recommended to remove
any dust accumulated in and around the appliance
before and after working on it. When servicing the
appliance it is recommended that the replaced
items are not broken up, but are sealed within
heavy duty polythene bags and labelled as RCF
waste.
RCF waste is classed as stable, non-reactive
hazardous waste and may be disposed of at a
licensed landfill site.
Excessive exposure to these materials may cause
temporary irritation to eyes, skin and respiratory
tract; wash hands thoroughly after handling the
material.
User Instructions
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Riva 2 F670 Balanced Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Riva 2 F670 Balanced Flue in the language / languages: English as an attachment in your email.

The manual is 4.76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info