813484
15
Zoom out
Zoom in
Previous page
1/48
Next page
15
SITE REQUIREMENTS
FLUE & CHIMNEY REQUIREMENTS
The chimney or flue system must comply with the rules in force,
and must be a minimum of 127mm (5") in diameter.
The minimum flue height for the appliance must be 3 metres (10ft).
Any horizontal flue run from the rear outlet must not exceed
100mm from the back of the appliance.
A minimum of 100mm vertical flue above the top outlet spigot
should be provided before any offset of the flue.
The chimney or flue must be free from any obstruction. Any
damper plates must be removed or secured in the fully open
position, and no restrictor plates fitted.
The chimney must be swept prior to the installation, but it need not
be swept if it can be seen the chimney is clean and unobstructed
throughout its entire length.
A 5" (127mm) liner must be used if fitting the appliance into an
existing brick built chimney.
Larger lined flues can work, but in some instances could cause
cold start flue problems resulting in nuisance shutdown. Lined flues
above 7" (175mm) are not recommended.
The European chimney standards now describe chimneys and
flues by their temperature, pressure and resistance to corrosion,
condensation and fire. To identify the correct flue system, the
minimum flue specification is shown in the Technical Specification.
Existing chimneys are not covered by this system.
FLUE OPTIONS
A range of Vitreous Enamel Gloss Black flue pipe is available
to compliment the Huntingdon. Please contact your Gazco
retailer for further information.
GAS SUPPLY
THIS APPLIANCE IS INTENDED FOR USE ON A GAS
INSTALLATION WITH A GOVERNED METER.
Before installation, ensure that the local distribution conditions
(identification of the type of gas and pressure) and the adjustment
of the appliance are compatible.
Ensure the gas supply delivers the required amount of gas and is
in accordance with the rules in force.
You can use soft copper tubing on the installation and soft soldered
joints outside the appliance and below the fire.
A means of isolating the gas supply to the appliance must be
provided independent of any appliance control.
All supply gas pipes must be purged of any debris that may have
entered prior to connection to the appliance.
The gas supply must be installed in a way that does not restrict the
removal of the appliance for servicing and inspection.
VENTILATION
IMPORTANT: Ensure any national ventilation requirements are
taken into account during installation of the appliance.
UK ONLY:
The Huntingdon 30 has a nominal input not exceeding 7.0kW and
does not normally require any additional permanent ventilation.
FOR THE REPUBLIC OF IRELAND REFER TO THE RULES IN
FORCE FOR VENTILATION REQUIREMENTS.
CO ALARMS
Building regulations require that whenever a new or replacement
fixed gas burning appliance is installed in a dwelling, a carbon
monoxide alarm complying with BS EN 50291-1(latest edition)
must be fitted in the same room as the appliance. Further guidance
and recommendations on the installation of carbon monoxide
alarms is available in BS EN 50292 (latest edition) and from
manufacturers’ instructions.
Provision of an alarm must not be considered a substitute for
either installing the appliance correctly or ensuring regular
servicing and maintenance of the appliance.
APPLIANCE LOCATION
Building Regulations state this appliance must stand on a non-
combustible hearth that is at least 12mm thick and projects 50mm
minimum from the base of the appliance in all directions, however
Gazco recommend the hearth extends to the following dimensions.
C
A
B
DIMENSION A B C
Huntingdon 20 716 420 12
Huntingdon 30 853 451 12
Huntingdon 40 941 482 12
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Huntingdon 20-30-40 - Conventional Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Huntingdon 20-30-40 - Conventional Flue in the language / languages: English as an attachment in your email.

The manual is 13.82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info